PURPOSE To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. METHODS Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refraction was measured using a Grand Seiko open-field autorefractometer across the central 60° of the horizontal visual field. Ocular aberrations were measured with a Hartman-Shack aberrometer, and monocular contrast sensitivity function (CSF) was measured with a VCTS6500 without and with the three contact lenses. RESULTS Both experimental lenses were able to increase significantly the relative peripheral myopic defocus up to -0.50 D in the nasal field and -1.00 D in the temporal field (p<0.05). The ExpRGP induced a significantly higher myopic defocus in the temporal field compared to the ExpSCL. ExpSCL induced significantly lower levels of Spherical-like HOA than ExpRGP for the 5mm pupil size (p<0.05). Both experimental lenses kept CSF within normal limits without any statistically significant change from baseline (p>0.05). CONCLUSIONS RGP lens design seems to be more effective to induce a significant myopic change in the relative peripheral refractive error. Both lenses preserve a good visual performance. The worsened optical quality observed in ExpRGP was due to an increased coma-like and spherical-like HOA. However, no impact on the visual quality as measured by CSF was observed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of astigmatism with contact lenses.

Contact lens correction of astigmatism is reviewed. According to literature data, rigid gas permeable lenses are the lenses of choice in correction of irregular and high astigmatism. The crucial advantage of rigid gas permeable lenses is clear vision and stable correction of astigmatism. Soft toric lenses ensure quick adaptation and comfort. The most prominent disadvantage of soft toric contact...

متن کامل

The effect of a new rigid gas-permeable contact lens design on lactic dehydrogenase activity in rabbit tears.

BACKGROUND Most corneal damage induced by contact lenses is due to interference with corneal oxygenation. OBJECTIVE To investigate the effect on the rabbit cornea of a rigid gas-permeable contact lens with a newly designed periphery. METHOD We fitted New Zealand white rabbits (n = 12) with RGP contact lenses that were identical in all respects except for the design of the periphery. In each...

متن کامل

Contact lens rehabilitation following repaired corneal perforations

BACKGROUND Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. METHOD Eyes that had undergone repair for corneal perforating injuries with or wit...

متن کامل

Rigid Gas Permeable Contact Lens as a Vision-Sparing Tool in Children After Traumatic Corneal Laceration.

PURPOSE To evaluate the clinical value of rigid gas permeable contact lenses in children after traumatic corneal scarring. METHODS This comparative study included 15 children (age range: 5.7 to 14 years; mean ± standard deviation = 9.4 ± 2.9 years) with corneal scars and best corrected visual acuity (BCVA) of worse than 20/20, history of penetrating ocular trauma, and/or cataract extraction. ...

متن کامل

On-eye evaluation of optical performance of rigid and soft contact lenses.

A Shack-Hartmann aberrometer was used to assess the optical performances of eyes corrected with rigid or soft contact lenses compared with spectacles. Metrics of optical quality derived from the measured wave aberrations were consistent with the subjective rating of visual clarity by subjects. Optical aberration analysis illustrated the differences in aberration structures of eyes wearing diffe...