Comparison of freehand 3-D ultrasound calibration techniques using a stylus.

نویسندگان

  • Po-Wei Hsu
  • Graham M Treece
  • Richard W Prager
  • Neil E Houghton
  • Andrew H Gee
چکیده

In a freehand 3-D ultrasound system, a probe calibration is required to find the rigid body transformation from the corner of the B-scan to the electrical center of the position sensor. The most intuitive way to perform such a calibration is by locating fiducial points in the scan plane directly with a stylus. The main problem of this approach is the difficulty in aligning the tip of the stylus with the scan plane. The thick beamwidth makes the tip of the stylus visible in the B-scan, even if the tip is not exactly at the elevational center of the scan plane. We present a novel stylus and phantom that simplify the alignment process for more accurate probe calibration. We also compare our calibration techniques with a range of styli. We show that our stylus and cone phantom are both simple in design and can achieve a point reconstruction accuracy of 2.2 mm and 1.8 mm, respectively, an improvement from 3.2 mm and 3.6 mm with the sharp and spherical stylus. The performance of our cone stylus and phantom lie between the state-of-the-art Z-phantom and Cambridge phantom, where accuracies of 2.5 mm and 1.7 mm are achieved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Freehand Three-Dimensional Ultrasound Calibration

Freehand three-dimensional (3D) ultrasound is a technique for acquiring ultrasonic data of a 3D volume with application in radiotherapy and surgery planning. As the clinician sweeps the ultrasound probe over the anatomy, the trajectory of the probe is recorded using an attached position sensor. However, the position sensor tracks the position of the sensor, rather than the ultrasound B-scan. It...

متن کامل

High Resolution Freehand 3 D Ultrasound

This paper describes a high resolution freehand 3D ultrasound system, whose accuracy surpasses that of previously documented systems. Such accuracy is achieved through a series of novel system design and calibration techniques. The accuracy is quantified using a purpose-built, tissue-mimicking phantom, designed to create idealised in vivo scanning conditions. The paper includes a thorough discu...

متن کامل

A review of calibration techniques for freehand 3-D ultrasound systems.

Three-dimensional (3-D) ultrasound (US) is an emerging new technology with numerous clinical applications. Ultrasound probe calibration is an obligatory step to build 3-D volumes from 2-D images acquired in a freehand US system. The role of calibration is to find the mathematical transformation that converts the 2-D coordinates of pixels in the US image into 3-D coordinates in the frame of refe...

متن کامل

Freehand 3D Ultrasound Calibration: A Review

Freehand three-dimensional ultrasound is a technique for acquiring ultrasonic data of a 3D volume by recording the trajectory of the ultrasound probe using a position sensor. In planning and registration, a freehand ultrasound systems is used to track a two-dimensional probe. Probe calibration is necessary to find the rigid body transformation from the coordinate system of the B-scan to that of...

متن کامل

Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system

BACKGROUND Freehand 3D ultrasound is a powerful imaging modality with many potential applications. However, its reliance on add-on position sensors, which can be expensive, obtrusive and difficult to calibrate, is a major drawback. Alternatively, freehand 3D ultrasound can be acquired without a position sensor using image-based techniques. Sensorless reconstructions exhibit good fine scale deta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2008