Tissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection

نویسندگان

  • Daniel W. Good
  • Ashfaq Khan
  • Steven Hammer
  • Paul Scanlan
  • Wenmiao Shu
  • Simon Phipps
  • Simon H. Parson
  • Grant D. Stewart
  • Robert Reuben
  • S. Alan McNeill
چکیده

INTRODUCTION Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection. MATERIAL AND METHODS Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E). Image analysis was performed with Image Pro Premier to determine the histology at each measurement point. RESULTS Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = < 0.001). Intra-class correlation (ICC) reliability tests showed good reliability (average ICC = 0.851). Sensitivity and specificity for tissue identification was 77% and 70% respectively to a resolution of 6 mm2. CONCLUSIONS This cadaveric study has evaluated the ability of our elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to examine the use of elasticity assessment devices for tissue quality assessment with the aim of giving haptic feedback to surgeons performing complex surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

آموزش تعهد حرفه ای در درس آناتومی و سالن تشریح جسد

Introduction: Medical ethics and professionalism is not limited to clinical course. With the implementation of vertical integration strategy in medical education in the 21st century, concepts such as professionalism, critical thinking, effective communication, collaboration and self-directed learning can be educated in basic sciences too. Methods: In this review article, the key words &quot;ca...

متن کامل

Mastoidectomy performance assessment of virtual simulation training using final-product analysis.

OBJECTIVES/HYPOTHESIS The future development of integrated automatic assessment in temporal bone virtual surgical simulators calls for validation against currently established assessment tools. This study aimed to explore the relationship between mastoidectomy final-product performance assessment in virtual simulation and traditional dissection training. STUDY DESIGN Prospective trial with bl...

متن کامل

Potential health risk assessment of some heavy metals (lead ,Nickel, Zink, Copper and Iron) in muscle of Silago Sihama in Qeshm, Khamir Port and Pol Port, Hormozgan

In recent years, anthropogenic and natural activities have caused high levels of metal contamination into the aquatic ecosystem. These pollutants can accumulate in the food chain. The present study examined the amount of metals such as lead ,Nickel, Zink, Copper and Iron in the muscle tissue of Silago Sihama because of their importance in three regions of the Hormozgan province.Sampling was don...

متن کامل

GIS Assessment of site suitability for serial biological concentration (SBC) in Murrumbidgee in Australia

Researchers of CSIRO Land and Water in Griffith in Australia have found a way to repeatedly reuse drainage water to grow crops. In the process the system will concentrate the salt in the water to a manageable level which can then be used or stored in an environmentally friendly manner. The process, known as sequential biological concentration, is based on a novel system for Land, based treatmen...

متن کامل

A Novel Image Structural Similarity Index Considering Image Content Detectability Using Maximally Stable Extremal Region Descriptor

The image content detectability and image structure preservation are closely related concepts with undeniable role in image quality assessment. However, the most attention of image quality studies has been paid to image structure evaluation, few of them focused on image content detectability. Examining the image structure was firstly introduced and assessed in Structural SIMilarity (SSIM) measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014