Psychophysical Measurements of Luminance Contrast Sensitivity and Color Discrimination with Transparent and Blue-Light Filter Intraocular Lenses

نویسندگان

  • Marcelo Fernandes da Costa
  • Augusto Paranhos Júnior
  • Claudio Luiz Lottenberg
  • Leonardo Cunha Castro
  • Dora Fix Ventura
چکیده

INTRODUCTION The purpose of this study was to measure luminance contrast sensitivity and color vision thresholdfs in normal subjects using a blue light filter lens and transparent intraocular lens material. METHODS Monocular luminance grating contrast sensitivity was measured with Psycho for Windows (version 2.36; Cambridge Research Systems) at 3.0, 6.0, 12.0, 20.0, and 30.0 cycles per degree of visual angle (cpd) in 15 normal subjects (eight female), with a mean age of 21.6 years (SD = 3.8 years). Chromatic discrimination was assessed with the Cambridge colour test (CCT) along the protan, deutan, and tritan color confusion axes. Both tests were performed in a darkened room under two situations: with a transparent lens and with blue light filter lens. Subjective impressions were taken by subjects regarding their visual experience under both conditions. RESULTS No difference was found between the luminance contrast sensitivity measured with transparent and blue light filter. However, 13/15 (87%) of the subjects reported more comfortable vision with the blue filter. In the color vision test, tritan thresholds were significantly higher for the blue filter compared with the transparent filter (p = 0.003). For protan and deutan thresholds no differences were found. CONCLUSION Blue-yellow color vision is impaired with the blue light filter, and no impairment occurs with the transparent filter. No significant differences in thresholds were found in the luminance contrast sensitivity comparing the blue light and transparent filters. The impact of short wavelength light filtering on intrinsically photosensitive retinal ganglion cells is also discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancement of contrast sensitivity and losses of chromatic discrimination with tinted lenses.

PURPOSE Tinted lenses for everyday use should not impair visual acuity and contrast sensitivity or cause radical changes in color perception. The main aim of this study was to compare the performance in contrast detection and color discrimination tasks of a set of tinted lenses with that of gray filters of equal luminance under D65. METHODS The contrast sensitivity functions of 10 observers w...

متن کامل

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation.

PURPOSE To compare contrast sensitivity and color vision in patients in whom blue-light filtering and non-yellow-tinted intraocular lenses (IOLs) were implanted. SETTING Refractive Surgery Unit, Hospital NISA Valencia al Mar, Valencia, Spain. METHODS Forty eyes of 20 patients were enrolled in a blue-light filtering fellow-eye control study; patients were implanted with a yellow-tinted IOL (...

متن کامل

The Evaluation of Yellow vs. Blue Color Contrast Sensitivity pre and Post LASIK

Introduction: contrast sensitivity is one of the most important psychophysical tests that may be used for the evaluation of refractive state of eye and retinal image quality. Yellow vs. blue color contrast sensitivity may be more suitable in this regard. Materials and Methods: thirty myopic eyes were considered in this study. Yellow vs. blue color contrast sensitivity was evaluated under the sa...

متن کامل

The physiology of scotopic vision, contrast vision, color vision, and circadian rhythmicity: can these parameters be influenced by blue-light-filter lenses?

PURPOSE Evaluation of the potential effects of blue-light-filter lenses on sensory and physiologic factors. METHODS Scientific knowledge on circadian rhythm and scotopic vision will be summarized and potential effects of blue-light-filtering lenses on these parameters will be assessed on a theoretical basis. Clinically relevant studies will also be discussed. RESULTS As far as circadian rhy...

متن کامل

Comparison of Visual Performance with Photochromic, Yellow and Clear Intraocular Lenses

Purpose: To evaluate visual function in patients with different types of light-filtering intraocular lenses (IOLs) Methods: In this prospective comparative clinical study Cataract patients with different types of IOLs in Khatam-al-Anbia Eye Hospital, Mashhad were enrolled and followed for three months postoperatively. Corrected distance visual acuity (CDVA), color discrimination under photopic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017