A locking contoured plate for distal fibular fractures: mechanical evaluation in an osteoporotic bone model using screws of different length.

نویسندگان

  • Robert K Zahn
  • Michael Jakubietz
  • Sönke Frey
  • Stefanie Doht
  • Alexander Sauer
  • Rainer H Meffert
چکیده

Osteoporotic bone with poor mechanical capacity provides limited stability after fixation of ankle fractures. Stabilization with an implant providing increased fixation strength in osteoporotic bone could reduce failure rates of fixation and allow a more functional treatment. The purpose of this study was to evaluate a locking contoured plate for fixation of distal fibular fractures in comparison with a conventional contoured plate in an osteoporotic bone model. Eighty cylinders of osteoporotic bone surrogates were fixed with the two plates. We performed torque-to-failure and cyclic testing experiments using screws of different length with a Zwick/Roell testing machine. The locking system showed higher torque-to-failure and maximum torque levels as compared with the conventional plate in torque-to-failure experiments and torsional cyclic testing. The locking contoured plate provides improved fixation strength in the osteoporotic bone model. The locking system may be appropriate for fixation of distal fibular fractures, especially in osteoporotic bone with poor mechanical capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

A contoured locking plate: Biomechanical evaluation of an osteosynthesis for osteoporotic ankle fractures

Introduction Ankle fractures involving the distal fibula belong to the most common fractures. Operative treatment is indicated in unstable ankle fractures by open reduction and internal fixation with plate and screws. Especially in the elderly, the osteoporotic bone provides reduced stabilization of this fixation. Therefore, an implant providing improved mechanical stabilization could allow a m...

متن کامل

Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques.

Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simula...

متن کامل

Biomechanical Comparison of Osteoporotic Distal Radius Fractures Fixed by Distal Locking Screws with Different Length

OBJECTIVES To evaluate the postoperative stability of osteoporotic distal radius fractures fixed with distal locking screws with different length. METHODS A comminuted extra-articular dorsally unstable distal radius fracture, treated with volar locking plate system, was created. The 18 specimens were randomized into 3 groups based on distal locked screws with different length: Group A had uni...

متن کامل

Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study.

OBJECTIVES The purpose of this study was to compare the biomechanical properties of posterolateral antiglide plating and lateral locked plating for fixation of displaced short oblique fractures of the fibula in osteoporotic bone. METHODS Short oblique fractures of the distal fibula at the level of the syndesmosis were simulated with a fibular osteotomy and ligamentous sectioning in 18 paired ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied biomechanics

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2014