Breath Hold Phase Correction for Water-Fat Separated MR Thermometry Using B0 Field Changes

نویسندگان

  • C. R. Wyatt
  • B. J. Soher
  • J. R. MacFall
چکیده

Introduction Proton resonance frequency shift (PRFS) thermometry of the breast is often confounded not only by the presence of fat in the tissue but also by respiration-induced B0 changes even in the absence of detectable breast motion. We (and others) have measured B0 changes of up to 0.16ppm due to respiration[1] leading to temperature errors on the order of 16°C (due to the 0.01ppm/°C PRFS sensitivity). This error must be reduced to less than 1°C for hyperthermia treatment. The B0 changes can be reduced by performing breath-holds during the MR scans, but large differences between breath-holds (~0.03ppm) are often still present due to inconsistent volume of each breath hold. Since fat does not experience a thermally related PRFS effect, fat-water separation provides fat as a local reference material to estimate B0 changes between breath-holds. However, since a tumor is not likely to contain significant amounts of fat reference material, surrounding fat-water voxels must be used to extrapolate B0 changes into the tumor region. In this work, field fitting techniques used previously [2] are used to extrapolate fat referenced B0 changes measured using fat-water separation methods to B0 changes in a water-only simulated tumor in a fat-water breast phantom.. Materials and Methods A fat-water gelatin phantom was developed to mimic a breast consisting of a 4.25”x5.875” container filled with 85:15 fat-water gelatin. A 2” cylinder was placed through the center of the phantom filled with 100% water gelatin (to mimic a tumor). The phantom was placed in a breast radiofrequency hyperthermia applicator equipped with MR imaging surface coils surrounded by a water bolus of room-temperature D2O. The experiment was performed without heating to test just the B0 correction. A healthy male subject (IRB approved protocol) was positioned in the prone position on top of the applicator, with the chest of the subject approximately 1.3cm from the top of the phantom. During breath holds, a multi-echo gradient-echo sequence using a 1.5T MRI system (Signa, GE Medical Systems) acquired images with TEs of 15.4, 21.8, and 28.2ms, FOV=28cm, 128x128, NEX=2, BW=15.62 kHz, TR=50ms, and slice thickness = 5mm. The acquisition time of the sequence and length of the breath hold was 16 seconds, with nine breath holds performed. Separate fat and water images were created using the single peak IDEAL fat-water separation algorithm[3], which also creates a B0 map. Each B0 map was subtracted from subsequent breath-hold map and the field difference was converted to phase differences at the time of the first echo. The converted phase differences at several points within the fat-water part of the phantom were extrapolated to form a predicted phase change at all pixels of the image, using a minimum curvature surface method [2]. The extrapolated phase changes were then used to correct each breath-hold image by subtracting the estimated phase error from the actual phase. The corrected phase difference was then converted into equivalent temperature difference using the PRFS method. Results A MR image of the phantom with the reference locations marked is shown in Figure 1. A plot comparing the uncorrected temperature change and corrected temperature change across the nine breath holds is shown in Figure 2. Discussion: As seen from Figure 2, the B0 map extrapolation method reduces PRFS temperature errors between breath holds from a maximum of 5.55C to less than 0.53C. In addition, the fat-water separation method allows for temperature calculation in the fat using the water-fat frequency difference [4]. Therefore, this technique allows for a unique thermometry strategy in the breast, where fat-water separated images are acquired and used not only to calculate temperature in the fat but to correct conventional PRFS thermometry in the tumor for B0 induced phase changes. References: [1] Peters, N., et al. JMRI 29 (3): 731-735 [2] Wyatt, C., et. al. International Journal of Hyperthermia, 25(6): 422-433 (2009) [3] Reeder, SB., et al. MRM. 51: 35-45 (2004) [4] Soher, BJ., et al. 16 ISMRM , Toronto, p3018 (2008) 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model-Based Multi-Echo Water/Fat-Separated MR Thermometry

Model-Based Multi-Echo Water/Fat-Separated MR Thermometry Megan E Poorman, Chris J Diederich, Graham Sommer, Kim Butts Pauly, and William A Grissom Biomedical Engineering, Vanderbilt University, Nashville, TN, United States, Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States, Radiation Oncology, University of California, San Francisco, CA, United States, Radiology...

متن کامل

MR temperature imaging using PRF phase difference and a geometric model-based fat suppression method.

BACKGROUND Because protons in fat do not exhibit a temperature-dependent frequency shift, proton resonance frequency shift (PRFS)-based MR thermometry always suffers from disturbances due to the presence of fats or lipids. OBJECTIVE A new fat suppression method for PRFS-based MR thermometry is proposed to obtain accurate variation of phase angle. METHODS Similar to the approach of separatin...

متن کامل

PRF based MR-Thermometry on Abdominal Organs: A pragmatic comparison of referenceless vs multi-baseline

Introduction Reliable temperature and thermal-dose measurements using PRF based MR-thermometry for MR-guided ablation therapy on abdominal organs are complicated by the fact that the target moves through an inhomogeneous and time-variant magnetic field. Two correction approaches emerged recently as the most promising candidates to allow continuous real-time MR-thermometry under free-breathing c...

متن کامل

Three dimensional phase sensitive reconstruction for water/fat separation in MR imaging using inverse gradient

INTRODUCTION: Inand out-of-phase imaging is a useful tool in quantitative imaging of fat. Several approaches have been implemented to improve the original two point Dixon method [1], often by introducing an extra point to increase the reliability of the reconstruction hence increasing scan time. Recent papers have shown promising results with two point protocols [2,3] although in our experience...

متن کامل

3T-MRH1 spectroscopy for quantification of myocardial steatosis: relationship to metabolic profile and global myocardial function

Methods A research protocol was applied on 90 subjects, using a Siemens Verio 70 cm bore 3T-MRI scanner. All subjects were not known to have cardiac disease. MR spectroscopy was performed with water suppressed ECG gated point resolved spectroscopy (PRESS), TR/TE =1R-R/ 30ms. PRESS voxel was located in the septum at isovolumic phase of diastole. Short axis and 4-chamber Steady State Free Precess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009