Automated carbohydrate analysis of physiologic fluids.
نویسندگان
چکیده
Automated carbohydrate analysis can be useful clinicaHy in the research laboratory as an aid in understanding the fundamental role of carbohydrates in metabolism, including their pathologic significance. An analytic system being developed at our laboratory utilizes an automated carbohydrate analyzer to chromatograph borated physiologic fluids while using strongly basic anion-exchange resin. The eluted carbohydrates are detected by sulfuric acid-phenol colorimetry. The carbohydrate analyzer used in this experimental work should become a useful tool in the clinical laboratory. Normal and diabetic human urine and blood serum have been chromatographed and significant differences established. As many as 38 peaks have been observed in the complex urine chromatograms. Using cochromatographic technics, 14 peaks have been tentatively identified as sucrose, raffinose, N-acetylglucosamine, maltose, lactose, ribose, fructose, arabinose, fucose, galactose, xylose, mannoheptulose, glucose, and glucose-i-phosphate. All except fucose have been quantified. Blood serum chromatograms consist of a major glucose peak and several smaller peaks indicating traces of other sugars. Melibiose has been used as an internal standard in chromatograms to determine recovery, resolution, and reproducibility. With the present technic, the lower limit of detectable sugar in physiologic fluids is in the l-i’.g. range.
منابع مشابه
Clinical and Experimental Hypertension
composition and of ion-exchange resin properties, both very valuable to the amino acid analyst. Detection reagents are evaluated, and gas-chromatographic methods are detailed. There is a good chapter on the important subject of computer application to amino acid analysis. The 46-page chapter on amino acids in physiologic fluids includes methods of a-amino nitrogen and individual methods for phe...
متن کاملCost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems
This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...
متن کاملHydration in soccer: a review
Hydration should be considered before, during and after the exercise. This review intends to approach the main points of hydration process in soccer. The replacement of fluids during exercise is proportional to some factors, such as: exercise intensity; climatic conditions; the athlete’s acclimatization; the athlete’s physical conditioning; physiologic individual characteristics and the player’...
متن کاملچالشهای برنامه زایمان فیزیولوژیک از دیدگاه ارایهدهندگان خدمت: مطالعه کیفی
Background & Aim: The physiologic childbirth program in Iran is an emerging program that needs to be evaluated like any other program to improve its quality and process. Evidence suggests that the implementation of the physiologic childbirth program faces some challenges. The present research aimed to explore the challenges of the physiologic childbirth program from the perspective of service p...
متن کاملSemi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis
Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT. We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS). ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 14 6 شماره
صفحات -
تاریخ انتشار 1968