Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The ‘fix and shift’ technique

نویسنده

  • P R Ramasamy
چکیده

BACKGROUND Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. MATERIALS AND METHODS Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. RESULTS Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. CONCLUSION Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Artificial dermis is not effective for resurfacing bone - exposing wounds ofGustilo ‒

1 According to the treatment of open fracture, the resurfacing of bone-exposing complex 2 wounds of Gustilo-Anderson III B and C fracture remains challenging. To treat 3 bone-exposing wounds, artificial dermis has been effective. We evaluated the 4 outcome of adapting artificial dermis the resurfacing bone-exposing complex wounds 5 of Gustilo-Anderson III B and C fracture clinically. Seven pati...

متن کامل

Limb salvage talectomy for 3C Gustilo–Anderson fracture

Foot fractures vary in severity with complex midfoot fractures having poor morbidity rates and high amputation rates. Complex midfoot fractures are rarely reported since they are uncommon and only treated in specialist centres. Given the important role of the midfoot in foot function, reconstruction is preferable. Soft tissue management on the dorsal aspect of the foot poses further challenges ...

متن کامل

Minimally Invasive Plate Osteosynthesis for Open Fractures of the Proximal Tibia

BACKGROUND Relatively few studies have addressed plate osteosynthesis for open proximal tibial fractures by now. The purpose of this study was to assess the results of minimally invasive plate osteosynthesis (MIPO) for open fractures of the proximal tibia. METHODS Thirty-four patients with an open proximal tibial fracture were treated by MIPO. Thirty of these, who followed for over 1 year, co...

متن کامل

Bone grafting via reamer-irrigator-aspirator for nonunion of open Gustilo-Anderson type III tibial fractures treated with multiplanar external fixator

INTRODUCTION The purpose of this investigation was to evaluate the outcomes following reamer-irrigator-aspirator (RIA) autogenous bone grafting (ABG) of high-grade open tibia fracture nonunions stabilized via multiplanar external fixation. METHODS We retrospectively reviewed all patients with Gustilo-Anderson type III open tibia fractures treated with multiplanar external fixation and who und...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2017