Robust Hand-Eye Calibration of an Endoscopic Surgery Robot Using Dual Quaternions

نویسندگان

  • Jochen Schmidt
  • Florian Vogt
  • Heinrich Niemann
چکیده

This paper presents an approach for applying a dual quaternion hand– eye calibration algorithm on an endoscopic surgery robot. Special focus is on robustness, since the error of position and orientation data provided by the robot can be large depending on the movement actually executed. Another inherent problem to all hand–eye calibration methods is that non–parallel rotation axes must be used; otherwise, the calibration will fail. Thus we propose a method for increasing the numerical stability by selecting an optimal set of relative movements from the recorded sequence. Experimental evaluation shows the error in the estimated transformation when using well–suited and ill–suited data. Additionally, we show how a RANSAC approach can be used for eliminating the erroneous robot data from the selected movements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous robot-world and hand-eye calibration using dual-quaternions and Kronecker product

Two solutions of the homogeneous matrix equation AX=ZB, that allows a simultaneous computation of the transformations from robot world to robot base and from robot tool to robot wrist coordinate frames, are proposed. The presented methods introduce the Kronecker product and dual quaternions to solve the rotations and translations problem, simultaneously, with no propagation error. The experimen...

متن کامل

Hand-Eye Calibration Using Dual Quaternions

To relate measurements made by a sensor mounted on a mechanical link to the robot’s coordinate frame, we must first estimate the transformation between these two frames. Many algorithms have been proposed for this so-called hand-eye calibration, but they do not treat the relative position and orientation in a unified way. In this paper, we introduce the use of dual quaternions, which are the al...

متن کامل

Light fields for minimal invasive surgery using an endoscope positioning robot.

OBJECTIVES To generate a fast and robust 3-D visualization of the operation site during minimal invasive surgery. METHODS Light fields are used to model and visualize the 3-D operation site during minimal invasive surgery. An endoscope positioning robot provides the position and orientation of the endoscope. The a priori un-known transformation from the endoscope plug to the endoscope tip (ha...

متن کامل

Hand-Eye Calibration of SCARA Robots

In SCARA robots, which are often used in industrial applications, all joint axes are parallel, covering three degrees of freedom in translation and one degree of freedom in rotation. Therefore, conventional approaches for the handeye calibration of articulated robots cannot be used for SCARA robots. In this paper, we present a new linear method that is based on dual quaternions and extends the ...

متن کامل

Hand - Eye Calibration 1

{ Whenever a sensor is mounted on a robot hand it is important to know the relationship between the sensor and the hand. The problem of determining this relationship is referred to as the hand-eye calibration problem. Hand-eye calibration is important in at least two types of tasks: (i) map sensor centered measurements into the robot workspace frame and (ii) allow the robot to precisely move th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003