A split-field drift tube for separation and efficient fragmentation of biomolecular ions.
نویسندگان
چکیده
A new ion mobility instrument that incorporates a low-field region for ion separation and a high-field region for collisional activation is described. In this approach, mixtures of ions are separated based on differences in their mobilities in a approximately 20-cm-long low-field ( approximately 5 V cm(-)(1)) region of a drift tube. As the ions approach the drift tube exit, they are exposed to a large focusing potential drop; at high fields, ions are efficiently collisionally activated and dissociate as they exit the drift tube. We have demonstrated this approach by examining the fragmentation pattern for electrosprayed bradykinin ions. These studies show that the activation process is highly tunable; it is possible to modulate the field such that precursor ion mass spectra as well as several high-field collision-induced fragmentation patterns can be obtained. The approach also appears to be a simple means of activating protein ions, as demonstrated by examining electrosprayed myoglobin ions.
منابع مشابه
Development of field modulation in a split-field drift tube for high-throughput multidimensional separations.
A field modulation approach for high-throughput ion mobility/time-of-flight analyses of complex mixtures has been developed using a split-field drift tube. In this approach, complex mixtures of peptides, such as those that arise from tryptic digestion of protein mixtures, are separated by nanocolumn liquid chromatography, ionized by electrospray ionization, and analyzed by ion mobility/time-of-...
متن کاملAnalyzing the Behavior of Hybrid Steel System of Tube in Tube with Bracing and Belt Truss
Nowadays, due to the escalation in construction of high-rise structures, the need for selecting a proper resistant structural system against earthquake and wind has increased significantly. These systems should show an optimized use of materials and should be presented as a hard and efficient structure. A good example of a high efficient system in high-rise buildings can be indicated is, the tu...
متن کاملCollision-induced dissociation of mobility-separated ions using an orifice-skimmer cone at the back of a drift tube.
An ion mobility-mass spectrometry technique that incorporates a differentially pumped orifice-skimmer cone (OSC) region at the exit of the drift tube has been developed. The OSC region is similar in design to those used in electrospray ionization sources and offers improvements in ion transmission (by factors of approximately 5-10 compared with previous designs) and the ability to induce fragme...
متن کاملAn ion mobility/ion trap/photodissociation instrument for characterization of ion structure.
A new instrument that combines ion mobility spectrometry (IMS) separations with tandem mass spectrometry (MS(n)) is described. Ion fragmentation is achieved with vacuum ultraviolet photodissociation (VUV PD) and/or collision-induced dissociation (CID). The instrument is comprised of an approximately 1 m long drift tube connected to a linear trap that has been interfaced to a pulsed F(2) laser (...
متن کاملA scanning frequency mode for ion cyclotron mobility spectrometry.
A new operational mode for an ion cyclotron mobility spectrometry instrument is explored as a possible means of performing high-resolution separations. The approach is based on oscillating fields that are applied to segmented regions of a circular drift tube. Ions with mobilities that are resonant with the frequency of field application are transmitted while nonresonant species are eliminated. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 75 22 شماره
صفحات -
تاریخ انتشار 2003