Performance of a new real‐time continuous glucose monitoring system: A multicenter pilot study
نویسندگان
چکیده
AIMS/INTRODUCTION The present study aimed to investigate the performance of a new real-time continuous glucose monitoring system. MATERIALS AND METHODS Interstitial glucose levels were monitored for 7 days in 63 patients with type 1 or type 2 diabetes using the Medtrum A6 TouchCare® CGM System. Venous blood was collected on a randomized day of the wear period. Plasma glucose levels were measured as reference values. RESULTS Among 1,678 paired sensor-reference values, 90.5% (95% confidence interval 89.1-91.9%) were within ±20%/20 mg/dL of the reference values, with a mean absolute relative difference of 9.1 ± 8.7% (95% CI: 8.9-9.2%). The percentages of paired sensor-reference values falling within zone A and B of the Clarke error grid analysis (EGA) and the type 1 diabetes consensus EGA were 99.1 and 99.8%. Continuous EGA showed that the percentages of accurate readings, benign errors, and erroneous readings were 89.9, 6.3 and 3.8%, respectively. Surveillance EGA showed that 90.6, 9.2, and 0.2% of sensor-reference values with no, slight and lower moderate risk, respectively. The mean absolute relative difference was 16.6, and 96.0% of the sensor values fell within zones A and B of the consensus EGA for hypoglycemia. More than 85% of sensor values were within ±20%/20 mg/dL of reference values, the mean absolute relative difference was <11, and >99.5% of the sensor values fell in zones A and B of the consensus EGA. CONCLUSIONS The Medtrum real-time continuous glucose monitoring system was numerically and clinically accurate over a large glucose range across 7 days of wear.
منابع مشابه
A New Continuous Multi-State Reliability Model with Time Dependent Component Performance Rate
A CSS1†is a system with the continues-state components. When a component has the ability to obtain all the situations from completely working to completely failed, it named continues-state component. In the real world, performance rate of elements are continuous and decrease by time. Continuity of components causes infinite working states and grows up the system states. In this paper we propose...
متن کاملCombined insulin pump therapy with real-time continuous glucose monitoring significantly improves glycemic control compared to multiple daily injection therapy in pump naïve patients with type 1 diabetes; single center pilot study experience.
OBJECTIVES This study assessed the safety and clinical effectiveness of the training protocol for initiating insulin pump therapy with real-time continuous glucose monitoring (MiniMed Paradigm REAL-Time System) in a stepwise approach on pump naive subjects with type 1 diabetes compared to a control group who remained on multiple daily injection (MDI) therapy. METHODS This was a 15-week treat-...
متن کاملA pilot trial in pediatrics with the sensor-augmented pump: combining real-time continuous glucose monitoring with the insulin pump.
Real-time continuous glucose monitoring and the insulin pump have been combined into the Sensor-Augmented Pump system (Medtronic MiniMed, Northridge, CA). This short-term pilot trial demonstrated that pediatric subjects with type I diabetes improved mean hemoglobin A1c (A1c) and glucose levels and reduced hypoglycemia and hyperglycemia using the Sensor-Augmented Pump system.
متن کاملDesign and Evaluation of a Pressure and Temperature Monitoring System for Pressure Ulcer Prevention
Introduction Pressure ulcers are tissue damages resulting from blood flow restriction, which occurs when the tissue is exposed to high pressure for a long period of time. These painful sores are common in patients and elderly, who spend extended periods of time in bed or wheelchair. In this study, a continuous pressure and temperature monitoring system was developed for pressure ulcer preventio...
متن کاملAccuracy of a new real-time continuous glucose monitoring algorithm.
BACKGROUND Through minimally invasive sensor-based continuous glucose monitoring (CGM), individuals can manage their blood glucose (BG) levels more aggressively, thereby improving their hemoglobin A1c level, while reducing the risk of hypoglycemia. Tighter glycemic control through CGM, however, requires an accurate glucose sensor and calibration algorithm with increased performance at lower BG ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -