Pharmacokinetics and pharmacodynamics of tiotropium solution and tiotropium powder in chronic obstructive pulmonary disease

نویسندگان

  • JM Hohlfeld
  • A Sharma
  • JA van Noord
  • PJG Cornelissen
  • E Derom
  • L Towse
  • V Peterkin
  • B Disse
چکیده

The aim of the study was to characterize pharmacokinetics of tiotropium solution 5 µg compared to powder 18 µg and assess dose-dependency of tiotropium solution pharmacodynamics in comparison to placebo. In total 154 patients with chronic obstructive pulmonary disease (COPD) were included in this multicenter, randomized, double-blind within-solution (1.25, 2.5, 5 µg, and placebo), and open-label powder 18 µg, crossover study, including 4-week treatment periods. Primary end points were peak plasma concentration (Cmax,ss ), and area under the plasma concentration-time profile (AUC0-6h,ss ), both at steady state. The pharmacodynamic response was assessed by serial spirometry (forced expiratory volume in 1 second/forced vital capacity). Safety was evaluated as adverse events and by electrocardiogram/Holter. Tiotropium was rapidly absorbed with a median tmax,ss of 5-7 minutes postdosing for both devices. The gMean ratio of solution 5 µg over powder 18 µg was 81% (90% confidence interval, 73-89%) for Cmax,ss and 76% (70-82%) for AUC0-6h,ss , indicating that bioequivalence was not established. Dose ordering for bronchodilation was observed. Powder 18 µg and solution 5 µg were most effective, providing comparable bronchodilation. All treatments were well tolerated with no apparent relation to dose or device. Comparable bronchodilator efficacy to powder18 µg at lower systemic exposure supports tiotropium solution 5 µg for maintenance treatment of COPD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه درمان دارویی تیوتروپیوم و β2 آگونیست در افراد مبتلا به بیماری مزمن انسدادی ریه: مرور سیستماتیک و متاآنالیز

Introduction: The long-acting anticholinergic Tiotropium, which used in the treatment of patients with chronic obstructive pulmonary disease, prescribed once a day, unlike other bronchodilators that used several times a day for patients. The study was a systematic review that examined the effectiveness and safety of β2 Agonists and Tiotropium in the patients with chronic obstructive pulmon...

متن کامل

A systematic review of comparative studies of tiotropium Respimat® and tiotropium HandiHaler® in patients with chronic obstructive pulmonary disease: does inhaler choice matter?

BACKGROUND In many countries worldwide, the long-acting anticholinergic drug tiotropium is available as a dry powder formulation delivered by means of the HandiHaler® inhalation device and as an aqueous solution delivered via the Respimat® Soft Mist™ Inhaler. Tiotropium HandiHaler® is a single-dose, dry powder, breath-actuated inhaler that provides delivered doses and lung deposition of tiotrop...

متن کامل

Tiotropium Respimat(®) Soft Mist™ inhaler: a review of its use in chronic obstructive pulmonary disease.

The long-acting anticholinergic agent tiotropium bromide (Spiriva(®)) is available as a solution for inhalation via Respimat(®) Soft Mist™ Inhaler in the EU and various other countries for the treatment of chronic obstructive pulmonary disease (COPD). With the Respimat(®) Soft Mist™ Inhaler there is improved lung deposition of drug (allowing a reduced dosage compared with tiotropium HandiHaler(...

متن کامل

ADIS DRUG CLINICAL Q&A Tiotropium Respimat Soft Mist inhaler: a guide to its use in chronic obstructive pulmonary disease (COPD) in the EU

Tiotropium Respimat Soft Mist inhaler (Spiriva Respimat ) is indicated as a maintenance bronchodilator to relieve the symptoms of patients with chronic obstructive pulmonary disease (COPD) in the EU. The delivered drug dose is independent of inspiratory effort and the prolonged duration of the aerosol cloud should make the co-ordination of actuation and inhalation easier. In patients with COPD,...

متن کامل

Pharmacokinetics and tolerability (Study 1) with particular reference to ocular safety (Study 2) of tiotropium Respimat® Soft Mist™ Inhaler: findings from two dose-ranging studies in healthy men

Data are presented from two randomized, double-blind, placebo-controlled studies in which the tolerability of tiotropium Respimat Soft MistTM Inhaler (SMI), a new-generation, propellant-free device for use in COPD, and the ocular safety oftiotropium were examined. In Study 1, 36 healthy males received tiotropium 8, 16, or 32 microg (n = 9/dose) or placebo (n = 3/dose level), administered once d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2014