Direct measurement of the formation length of photons.
نویسندگان
چکیده
We report the first observation of a shoulder in the radiation spectrum from GeV electrons in a structured target consisting of two thin and closely spaced foils. The position of the shoulder depends on the target spacing and is directly connected to the finite formation length of a low-energy photon emitted by an ultrarelativistic electron. With the present setup it is possible to control the separation of the foils on a μm scale and hence measure interference effects caused by the macroscopic dimensions of the formation length. Several theoretical groups have predicted this effect using different methods. Our observations have a preference for the modified theory by Blankenbecler but disagree with the results of Baier and Katkov.
منابع مشابه
A Non-Demolition Photon Counting Method by Four-Level Inverted Y-Type Atom
The semi-classical model of atom-field interaction has been fully studied for some multilevel atoms, e.g. Vee, L, Cascade X , Y, and inverted Y and so on. This issue is developed into the full-quantum electrodynamics formalism, where the probe and coupling electromagnetic fields are quantized. In this article, we investigate the full-quantum model of absorption and dispersion spectrum of trappe...
متن کاملEstimation of sedimentation and erosion using MPSIAC, FSM and direct measurement methods in Gabric watershed, South-eastern of Iran
Extended abstract 1- Introduction Soil erosion, as one of the most important environmental problems in the world, has a devastating effect on all life, natural resources and it's under human management. Considering that one of the important goals in the management of drainage of basins such as Gabric basin is preventing soil erosion, and also one of the important factors when designing d...
متن کاملAccuracy of an Intraoral Digital System for File Length Measurement
Introdouction: Canal length measurement is essential for proper endodontic treatment. Any error or miscalculation in working length determination, particularly in curved canals, can result in complications during or after root canal therapy. Digital radiography has enabled accurate measurement of curved canal length. In this study, we evaluated the accuracy of calibration of a complementary m...
متن کاملارزیابی دقت یک نوع Electronic Apex Locator در تعیین طول دندانهای شیری (In-vitro)
Statement of Problem: Radiography is the most common technique in working length determination, however, because of its limitations is not considered as an ideal technique. Its application, particularly for children due to radiation hazards, technical problems in young and unco-operative children and the superimposition of permanent teeth bud on primary teeth root, lead to numerous problems.Pur...
متن کاملDetermination of the attenuation coefficient for megavoltage photons in the water phantom
Background: Attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. So, its exact measurement or calculation is very important. The aim of this study was to evaluate the μ in different points in the water phantom anal...