Fixation for metacarpal neck fracture: a biomechanical study.

نویسندگان

  • Pramote Malasitt
  • John R Owen
  • Marc-Antoine Tremblay
  • Jennifer S Wayne
  • Jonathan E Isaacs
چکیده

BACKGROUND There is no robust evidence of the best operative treatment for displaced unstable metacarpal neck fractures. Numerous constructs are used in the fixation of metacarpal neck fractures. Currently, two common methods are dorsal locking plate and K-wire fixation. A new metacarpal sled fixation system for metacarpal neck fracture was designed to provide fracture stability but limit dissection and avoid exposed hardware. The purpose of this study was to compare the biomechanical integrity of the metacarpal sled versus standard locking plate fixation and retrograde K-wire fixation in a simulated porcine metacarpal fracture model. METHODS Transverse metacarpal neck fractures were created in 30 porcine second metacarpals. The specimens were randomly fixed with locking plates, metacarpal sleds, or retrograde K-wires. Constructs were then loaded to failure in three-point bending. Stiffness and peak load were measured from the load-to-failure deflection curve. Data were analyzed via ANOVA, followed by Tukey-Kramer's post hoc pairwise comparison. RESULTS The K-wire group had the highest initial stiffness followed by the sled group and then the plate group. Statistical difference was only found between K-wires and plate. Peak load for the K-wire group was lowest, followed by sled, and then by plate. A statistically significant difference was observed between the peak loads of the K-wires and plate, as well as the sled and plate. However, a difference in peak load was not detected between the K-wires and sled. CONCLUSIONS For transverse metacarpal neck fractures, a metacarpal sled construct provides similar fixation to K-wires with limited dissection and without exposed hardware or the potential for soft tissue tethering. The new low profile construct using a minimally invasive technique would be suitable for unstable metacarpal neck fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of Unicortical versus Bicortical Metacarpal Fracture Internal Fixation Trial (SUBMIT): study protocol for a randomized controlled trial

BACKGROUND Metacarpal fractures are common, accounting for 40 % of all hand injuries. The use of plates for the fixation of these fractures allows early aggressive hand therapy post-operatively, reducing post-operative stiffness. Traditionally, bicortical fixation is the standard practice, where both dorsal and palmar cortices of the metacarpal are drilled through, with screws engaging both cor...

متن کامل

Standard bicortical screw fixation is not superior to monocortical fixation using mini-locking plates: a biomechanical study in a metacarpal fracture model

Standard bicortical screw fixation is not superior to monocortical fixation using mini-locking plates: a biomechanical study in a metacarpal fracture model Sabine Ochman1, Stefanie Doht2, Juergen Paletta3, Martin Langer1, Michael J. Raschke1, Rainer H. Meffert1 1Trauma, Hand and Reconstructive Surgery, University of Muenster, Muenster, Germany; 2Trauma-, Hand-, Plasticand Reconstructive Surgery...

متن کامل

A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading.

The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse mi...

متن کامل

Role of soft tissues in metacarpal fracture fixation.

The contribution of soft tissues in stabilizing fracture fixation in metacarpals is appreciated clinically, but no quantitative biomechanical study of their role has been done. All previous studies of fracture fixation in vitro have been done on metacarpals denuded of soft tissues. To quantify the role of soft tissues in metacarpal fracture fixation, the biomechanical effectiveness of four fixa...

متن کامل

Biomechanical Analysis of the Efficacy of Locking Plates during Cyclic Loading in Metacarpal Fractures

PURPOSE To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. METHODS Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hand

دوره 10 3  شماره 

صفحات  -

تاریخ انتشار 2015