Hemodynamic effects of nasal CPAP examined by Doppler echocardiography.
نویسندگان
چکیده
The effects of incremental application of nasal continuous positive airway pressure (0 to 15 cm H2O) on heart rate, pulmonary artery pressure, and cardiac index were studied noninvasively by Doppler echocardiography. By two-way analysis of variance within two groups (19 normal volunteers and six sleep apnea patients), no significant effects on heart rate, pulmonary artery pressure, ventricular size, or cardiac index could be found with increasing positive intrathoracic pressures and consequent lung hyperinflation. In subjects with normal cardiac function, nasal CPAP is safe from a hemodynamic viewpoint. This simple, repeatable and noninvasive technique may be used to assess the clinical safety and efficacy of prescribed nasal CPAP on cardiac hemodynamics in individual patients.
منابع مشابه
Normal Echocardiographic Findings in Healthy Pigeons
Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...
متن کاملEffects of CPAP on right ventricular myocardial performance index in obstructive sleep apnea patients without hypertension
OBJECTIVES Obstructive sleep apnoea (OSA) might cause right ventricular dysfunction and pulmonary hypertension. We aimed to determine the effects of nasal continuous positive airway pressure (CPAP) therapy on right ventricular myocardial performance index (MPI) in OSA patients without hypertension. METHODS 49 subjects without hypertension, diabetes mellitus, any cardiac and pulmonary disease ...
متن کاملContinuous positive airway pressure (CPAP) consequences on right heart function and serum biomarkers in obstructive sleep apnea assessed by tricuspid annular plane systolic excursion (TAPSE) and color tissue doppler imaging
We sought to demonstrate preclinical adverse cardiac and systemic effects of Obstructive Sleep Apnea (OSA) improve with Continuous Positive Airway Pressure (CPAP) utilizing known biomarkers and echocardiographic measures. Our goal was to determine which measures would have utility in monitoring effectiveness of CPAP therapy. Subjects were recruited from a tertiary academic medical center with o...
متن کاملDoppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملThe Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP) in Premature Neonates: A Cross-Over Clinical Trial Study
Background The most common cause of admission to neonatal intensive care units (NICU) is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP). Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 99 2 شماره
صفحات -
تاریخ انتشار 1991