Patient–ventilator asynchrony during conventional mechanical ventilation in children
نویسندگان
چکیده
BACKGROUND We aimed (1) to describe the characteristics of patient-ventilator asynchrony in a population of critically ill children, (2) to describe the risk factors associated with patient-ventilator asynchrony, and (3) to evaluate the association between patient-ventilator asynchrony and ventilator-free days at day 28. METHODS In this single-center prospective study, consecutive children admitted to the PICU and mechanically ventilated for at least 24 h were included. Patient-ventilator asynchrony was analyzed by comparing the ventilator pressure curve and the electrical activity of the diaphragm (Edi) signal with (1) a manual analysis and (2) using a standardized fully automated method. RESULTS Fifty-two patients (median age 6 months) were included in the analysis. Eighteen patients had a very low ventilatory drive (i.e., peak Edi < 2 µV on average), which prevented the calculation of patient-ventilator asynchrony. Children spent 27% (interquartile 22-39%) of the time in conflict with the ventilator. Cycling-off errors and trigger delays contributed to most of this asynchronous time. The automatic algorithm provided a NeuroSync index of 45%, confirming the high prevalence of asynchrony. No association between the severity of asynchrony and ventilator-free days at day 28 or any other clinical secondary outcomes was observed, but the proportion of children with good synchrony was very low. CONCLUSION Patient-ventilator interaction is poor in children supported by conventional ventilation, with a high frequency of depressed ventilatory drive and a large proportion of time spent in asynchrony. The clinical benefit of strategies to improve patient-ventilator interactions should be evaluated in pediatric critical care.
منابع مشابه
A randomized clinical trial of neurally adjusted ventilatory assist versus conventional weaning mode in patients with COPD and prolonged mechanical ventilation
BACKGROUND Patient-ventilator asynchrony is a common problem in mechanically ventilated patients; the problem is especially obvious in COPD. Neutrally adjusted ventilatory assist (NAVA) can improve patient-ventilator asynchrony; however, the effect in COPD patients with prolonged mechanical ventilation is still unknown. The goals of this study are to evaluate the effect of NAVA and conventional...
متن کاملNeurally adjusted ventilatory assist: a ventilation tool or a ventilation toy?
Mechanical ventilation has, since its introduction into clinical practice, undergone a major evolution from controlled ventilation to various modes of assisted ventilation. Neurally adjusted ventilatory assist (NAVA) is the newest development. The implementation of NAVA requires the introduction of a catheter to measure the electrical activity of the diaphragm (EA(di)). NAVA relies, opposite to...
متن کاملAsynchrony and dyspnea.
Patient-ventilator synchrony and patient comfort are assumed to go hand in hand, yet few studies provide support for this common sense idea. In reality, synchrony between the patient and ventilator is complex and can be affected by the ventilator settings, type of ventilator, patient-ventilator interface, and sedation. Inspections of airway pressure and flow waveforms are reliable methods for d...
متن کاملAssisted mechanical ventilation: the future is now!
Assisted ventilation is a highly complex process that requires an intimate interaction between the ventilator and the patient. The complexity of this form of ventilation is frequently underappreciated by the bedside clinician. In assisted mechanical ventilation, regardless of the specific mode, the ventilator's gas delivery pattern and the patient's breathing pattern must match near perfectly o...
متن کاملHow often does patient-ventilator asynchrony occur and what are the consequences?
Mechanical ventilation can be life-saving for patients with acute respiratory failure. In between the 2 extremes of complete and no ventilatory support, both patient and machine contribute to ventilatory work. Ideally, ventilator gas delivery would perfectly match patient demand. This patient-ventilator interaction depends on how the ventilator responds to patient respiratory effort and, in tur...