Selective radiography of 10B distribution in organs using cold and thermal neutron beams.
نویسندگان
چکیده
The investigation of boron biodistribution by neutron induced autoradiography was performed using a CR-39 etched track detector. Calibration samples, made of boronated chicken liver, and freeze-dried mouse tissue samples were irradiated both with thermal and cold neutrons. Digital images were made on the basis of track densities, with the selection of tracks due to 10B(n, alpha)7Li reaction. A comparison of results obtained both with thermal and cold neutrons demonstrated that it is possible to obtain equivalent results with both neutron sources, although the background noise due to recoil protons from the fast neutrons of the thermal neutron source is 15 % higher than that of the cold neutron source. 10B concentrations in the range of 0.5 ppm to 150 ppm were determined, with a standard deviation of 13 % and 8 % for the mouse tissue samples and calibration samples, respectively.
منابع مشابه
A Monte Carlo Study on the Effect of Various Neutron Capturers on Dose Distribution in Brachytherapy with 252Cf Source
Background: In neutron interaction with matter and reduction of neutron energy due to multiple scatterings to the thermal energy range, increasing the probability of thermal neutron capture by neutron captures makes dose enhancement in the tumors loaded with these materials. Objective: The purpose of this study is to evaluate dose distribution in the presence of 10B, 157Gd and 33S neutron...
متن کامل10B Concentration, Phantom Size and Tumor Location Dependent Dose Enhancement and Neutron Spectra in Boron Neutron Capture Therapy
Background: The amount of average dose enhancement in tumor loaded with 10B may vary due to various factors in boron neutron capture therapy.Objective: This study aims to evaluate dose enhancement in tumor loaded with 10B under influence of various factors and investigate the dependence of this dose enhancement on neutron spectra changes.Material and Methods: In this simulation stud...
متن کاملOptimum neutron energy simulation in treatment of head and neck cancer at different depths in the BNCT method
Introduction: Recently head and neck cancer has pay attention to many researchers. Its therapeutic methods include surgery, chemotherapy, radiotherapy and Boron neutron capture therapy (BNCT). BNCT is better than conventional radiotherapy because it targets the tumor cell. This method involves two steps of infusion of stable 10B and then neutron radiation with a suitable intens...
متن کاملThe influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method
Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...
متن کاملA COMPARISON BETWEEN THERMAL AND X RADIOGRAPHY FOR STUDYING THE INTERNAL STRUCTURE OF BIOLOGICAL
ABSTRACT Background: With respect to the difference in the interaction of thermal neutron and X rays with matter, using two radiography systems of thermal neutron and X rays will yield highly valuable information for studying the inner structure of biologic samples. Methods: The high sensitivity of thermal neutron to hydrogen, in particular, has led to recognizing this system as a useful tool ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cellular & molecular biology letters
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2002