Cost-effectiveness Analysis of Existing Pedicle Screws Reusing Technique in Extension Revision Operation for Adjacent Segmental Stenosis After Lumbar Posterolateral Fusion.

نویسندگان

  • Jin Kyu Lee
  • Young-Hoon Jo
  • Chang-Nam Kang
چکیده

STUDY DESIGN Retrospective case-control study. OBJECTIVE A cost-effectiveness analysis was performed by comparing patients who received extension revision operations for adjacent segment disease (ASD) reusing the pedicle screws extracted from fused segments with patients who received conventional surgery. SUMMARY OF BACKGROUND DATA ASD often required extension revision surgery, and during extension surgery, pedicle screws may be reused by extracting from the fused segments of primary surgery. METHODS Study examined 37 patients who received extension revision surgery for ASD from January 2003 to December 2013. For the fixation of extended segments during revision operation, in 16 cases the pedicle screws extracted from fused segments were reused (group R), and in 21 cases new pedicle screws were used (group C) as a conventional method. Clinical outcomes were evaluated by means of visual analog scale scores for lumbago and leg pain, and the Korean Oswestry Disability Index. Radiologic outcomes were evaluated from the extent of bone union. The total operating costs in the two groups were compared. RESULTS Visual analog scale scores for lumbago and leg pain, and the Korean Oswestry Disability Index measured at final follow-up averaged 3.6 and 3.8, and 19.9 in group R, and 3.8 and 3.1, and 21.1 in group C, respectively (P = 0.280, P = 0.387, P = 0.751). For radiologic outcomes, there was one case of nonunion in each group. The cost of surgery was 5332 US dollars in group R, and 6109 US dollars in group C, respectively (P = 0.036). CONCLUSION Reusing pedicle screws extracted from the fused segments during extension revision operation for ASD can reduce the cost of surgery, and achieves clinical and radiological results similar to those of the conventional operation. LEVEL OF EVIDENCE 4.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro biomechanical effects of reconstruction on adjacent motion segment: comparison of aligned/kyphotic posterolateral fusion with aligned posterior lumbar interbody fusion/posterolateral fusion.

OBJECT Posterior lumbar interbody fusion (PLIF) was developed to overcome the limitations of posterolateral fusion in correcting spinal deformity and maintaining lumbar lordosis. In this study the authors compare the biomechanical effects of three different posterior reconstructions on the adjacent motion segment. METHODS Ten calf spinal (L2-S1) specimens underwent nondestructive flexion-exte...

متن کامل

Distal junctional failure secondary to L5 vertebral fracture-a report of two rare cases.

Distal junctional failure (DJF) with fracture at the last instrumented vertebra is a rare occurrence. In this case report, we present two patients with L5 vertebral fracture post-instrumented fusion of the lumbar spine. The first patient is a 78-year-old female who had multi-level degenerative disc disease, spinal stenosis and degenerative scoliosis involving levels T12 to L5. She underwent ins...

متن کامل

Strategy for salvage pedicle screw placement: A technical note

BACKGROUND Salvage surgery for failed lumbar spine fusion with a loosened pedicle screw is challenging. In general, the strategy includes replacement with larger and longer pedicle screws, augmentation with polymethylmethacrylate cement or hydroxyapatite granules, and extension of fused segments. The purpose of this study is to introduce a new technique for pedicle screw replacement after faile...

متن کامل

Technical Note: The 80/20 Technique for Posterior Lumbar Interbody Fusion – A Combination of Open Decompression and Percutaneous Pedicle Screw Fixation

Objective: To illustrate a hybrid technique that involves a combination of open decompression and Posterior Lumbar Interbody Fusion (PLIF) and percutaneously placed pedicle screws. This technique allows for PLIF via a midline incision and approach, and decompression without compromise in operative time and visualisation. Furthermore, this approach is proposed to reduce post-operative wound pain...

متن کامل

Hybrid technique for posterior lumbar interbody fusion: a combination of open decompression and percutaneous pedicle screw fixation.

The authors describe a hybrid technique that involves a combination of open decompression and posterior lumbar interbody fusion (PLIF) and percutaneously inserted pedicle screws. This technique allows performance of PLIF and decompression via a midline incision and approach without compromising operative time and visualization. Furthermore, compared to standard open decompression, this approach...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Spine

دوره 41 13  شماره 

صفحات  -

تاریخ انتشار 2016