A multicentre study on the reliability of qualitative and quantitative nail-fold videocapillaroscopy assessment.

نویسندگان

  • Herman M A Hofstee
  • Erik H Serné
  • Christopher Roberts
  • Roger Hesselstrand
  • Agneta Scheja
  • Tonia L Moore
  • Marie Wildt
  • Joanne B Manning
  • Anton Vonk Noordegraaf
  • Alexandre E Voskuyl
  • Ariane L Herrick
چکیده

OBJECTIVE To investigate the inter- and intra-observer reliability of both qualitative and quantitative parameters used in the assessment of nail-fold capillaroscopy images. METHODS Fifty mosaic nail-fold images of healthy controls (n = 10), patients with primary RP (n = 10) and SSc (n = 30) were assessed in random order by two blinded observers on two occasions at centres in Sweden, UK and The Netherlands. Each image was therefore scored by six observers twice. RESULTS Inter- and intra-observer reliability of quantitative parameters showed substantial to almost perfect agreement [inter- and intra-observer weighted κ's for the number of widened capillaries was 0.75 and 0.87 and giant capillaries was 0.84 and 0.92, intra-class correlation coefficients (ICCs) for capillary density was 0.87 and 0.92 and total loop width was 0.94 and 0.98, respectively]. Qualitative parameters including architecture, avascularity, haemorrhage, crossed, ramified and bushy capillaries showed moderate to substantial inter-observer reproducibility (weighted κ ranging from 0.47 to 0.73), and substantial intra-observer repeatability (weighted κ ranging from 0.71 to 0.80), whereas the scoring of tortuous and bizarre capillaries showed poor inter-observer and substantial intra-observer agreement (inter-observer weighted κ's was 0.39 and 0.21 and intra-observer weighted κ's was 0.68 and 0.76, respectively). CONCLUSION All quantitative and certain qualitative parameters are highly reliable in terms of inter- and intra-observer agreement. A combination of parameters with the highest reliability should be incorporated into future capillaroscopic scoring systems in studies of prediction and monitoring of SSc spectrum disorders.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of the qualitative and semiquantitative nailfold videocapillaroscopy assessment in a systemic sclerosis cohort: a two-centre study.

OBJECTIVE Investigation of the reliability of the qualitative and semiquantitative scoring of nailfold videocapillaroscopy (NVC) assessment between two raters in a systemic sclerosis (SSc) cohort. METHODS Two raters from different centres blindly assessed the NVC images of 71 consecutive patients with SSc qualitatively as belonging to the scleroderma spectrum (SDS) category ('early', 'active'...

متن کامل

Preliminary Findings about Effectiveness of Aminapthone Therapy in Diabetic Microangiopathy

Objective: microangiopatic complications of Diabetes (Retinopathy, Nephropathy and Neuropathy) are an invalidant and social clinical problems in Diabetics. Aim of this study has been to verify if a treatment with an “endothelial-protector drug” like aminapthone, added to standard therapy, could be useful in controlling and delaying diabetic complications evaluated by nail fold periungueal video...

متن کامل

Construction and Validation of Self-Assessment Inventory for English for Academic Purposes: A Case of Iranian Tertiary Students

Self-assessment helps learners to acquire self-confidence and gives them insightfulfeedbacks. There is no valid self-assessment inventory for learners of English foracademic purposes (EAP). This study aimed at developing an academicallyappropriate instrument to measure tertiary students’ English in academic situations.The study used both qualitative and quantitative methods in developing the se...

متن کامل

Assessment of Qualitative and Quantitative Indexes of Clerkship Tests in General Medicine

Introduction: Using multiple choice question tests, as an objective testing method, is the most common students evaluation procedure , and it is very important to design these tests properly.This study aimed to assess clerkship tests of general medicine courses in the training group of dermatology, psychiatry, gynecology, ophthalmology and neurology of medical college of Isfahan University of M...

متن کامل

The influence of measurement location on reliability of quantitative nailfold videocapillaroscopy in patients with SSc.

OBJECTIVES Nailfold videocapillaroscopy is being increasingly used as a marker of SSc-related microvascular disease, including in response to treatment. However, it requires further validation. Our aim was to assess the inter-observer, intra-observer and test-retest variability of semi-automated measurement of capillary features as well as of a manual density measurement. METHODS All capillar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rheumatology

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2012