The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems.

نویسندگان

  • D Bolliger
  • L A Steiner
  • J Kasper
  • O A Aziz
  • M Filipovic
  • M D Seeberger
چکیده

We determined the accuracy of two transcutaneous carbon dioxide monitoring systems (SenTec Digital Monitor with V-Sign Sensor and TOSCA 500 with TOSCA Sensor 92) for the measurement of single values and trends in the arterial partial pressure of carbon dioxide in 122 adult patients during major surgery and in 50 adult patients in the intensive care unit. One or several paired measurements were performed in each patient. The first measurement was used to determine the accuracy of a single value of transcutaneous carbon dioxide; the difference between the first and the last measurements was used to analyse the accuracy and to track trends. We defined a 95% limit of agreement of <or=1 kPa as being clinically useful. There was insufficient agreement between transcutaneous carbon dioxide partial pressure values derived from the two systems and arterial carbon dioxide values for both single values and trends as defined by our suggested limit of agreement. We conclude that these systems cannot replace conventional blood gas analysis in the clinical setting studied.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

Vagus nerve stimulation in the treatment of nervous system disease: a review article

The vagus nerve (VN), the longest cranial nerve and an essential part of the parasympathetic system, connects the central nervous system to respiratory, cardiovascular, immune, gastrointestinal, and endocrine systems and is involved in the maintenance of homeostasis by controlling these systems. Vagus nerve stimulation (VNS) is related to any method that would stimulate the vagal nerve via elec...

متن کامل

Agreement of Mixed Venous Carbon Dioxide Tension (PvCO2) and Transcutaneous Carbon Dioxide (PtCO2) Measurements in Ventilated Infants

BACKGROUND Noninvasive transcutaneous carbon dioxide monitoring has been shown to be accurate in infants and children, limited data are available to show the usefulness and limitations of partial transcutaneous carbon dioxide tension (PtCO2) value. OBJECTIVES The current study prospectively determines the effectiveness and accuracy of PtCO2 measurements in newborns. MATERIALS AND METHODS Ve...

متن کامل

Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.

OBJECTIVE To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. DESIGN Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arteria...

متن کامل

Concordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting

Non-invasive monitoring of arterial oxygen using percutaneous pulse oximetry is well established. Although some studies show a good correlation of transcutaneous end-tidal carbon dioxide partial pressure (PetCO2) with arterial carbon dioxide partial pressure (PaCO2), they were performed in research settings and involved restricted populations such as paediatric, accident and emergency, or inten...

متن کامل