Normal range of left ventricular 2-dimensional strain: Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) study.

نویسندگان

  • Kiyohiro Takigiku
  • Masaaki Takeuchi
  • Chisato Izumi
  • Satoshi Yuda
  • Konomi Sakata
  • Nobuyuki Ohte
  • Kazuaki Tanabe
  • Satoshi Nakatani
چکیده

BACKGROUND To determine the normal range of left ventricular (LV) 2- dimensional (2-D) strain and vendor-specific differences, a multicenter prospective 2-D strain study endorsed by the Japanese Society of Echocardiography was conducted. METHODS AND RESULTS 2-D speckle tracking analysis was performed on 817 healthy subjects (age range, 0-88 years); the images included 3 LV short axis and 3 apical views using an ultrasound system from 1 of the 3 different vendors (V(1), n=333; V(2), n=330; V(3), n=337). With the 2-D speckle tracking software from each vendor, radial, circumferential and longitudinal strain were measured using an 18-segment model. Inter-vendor variability was also assessed in a subset of subjects. The feasibility for 2-D strain measurements was different among the 3 vendors (V(1), 83%; V(2), 70%; V(3), 88%, P<0.01). The global radial (V(1), 54.6±12.6%; V(2), 36.3±8.2%; V(3), 51.4±8.0%), circumferential (V(1), -22.8±2.9%; V(2), -22.2±3.2%; V(3), -30.5±3.8%), and longitudinal (V(1), -21.3±2.1%; V(2), -18.9±2.5%; V(3), -19.9±2.4%) strain measurements were significantly different for each of the vendors. Segmental strain was also different between the 3 vendors. On inter-vendor analysis, vendor agreement ranged from mild to moderate. CONCLUSIONS Reference values are provided for normal 2-D strain for 3 different ultrasound vendors. Due to a low inter-vendor agreement, 2-D strain data are not interchangeable when conducting a longitudinal follow-up or a cross-sectional assessment of LV function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Function and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking.

One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to c...

متن کامل

Left Ventricular Myocardial Function in Hemodialysis and Nondialysis Uremia Patients: A Three-Dimensional Speckle-Tracking Echocardiography Study

BACKGROUND Several studies have demonstrated that uremic patients who have preserved left ventricular ejection fraction (LVEF) could still have the potential for systolic dysfunction. The aim of this study was to assess the differences between the left ventricular (LV) myocardial function in hemodialysis and nondialysis uremic patients based on three-dimensional speckle-tracking echocardiograph...

متن کامل

Left Atrium Function in Systemic Hypertension

Objective: Assessment of left atrium (LA) deformation by 2-Dimensional Speckle Strain Imaging (2DSI) has been recently proposed as an alternative method of exploring LA function. The purpose of this study was to assess the relationship of LA function, particularly reservoir function, with LA structural remodeling related to left ventricular hypertrophy (LVH) in patients with hypertension (HTN) ...

متن کامل

Prosthetic valve endocarditis: multiple complications in one patient.

strain measurement with 2-dimensional speckle-tracking echocardiography: definition of normal range. Impact of myocardial structure and function postinfarction on diastolic strain measurements: Implications for assessment of myocardial viability.gression of left ventricular diastolic dysfunction and risk of heart failure. Normal ranges of left ven-tricular strain: a meta-analysis. Inter-study r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 76 11  شماره 

صفحات  -