Background Transcatheter Aortic Valve Implantation (TAVI) is increasingly used to treat patients with severe aortic stenosis at high surgical risk. The severity of post-implantation valvular or paravalvular regurgitation has been shown to adversely affect patient outcome. The aim of the study was to assess the prevalence and severity of aortic regurgitation (AR) at 6 months post-TAVI using cardiovascular magnetic resonance (CMR).
منابع مشابه
Multiparametric Assessment of Post-Transcatheter Aortic Valve Replacement Paravalvular Regurgitation Grading by Transthoracic Echocardiography and Cardiac Magnetic Resonance
Purpose: Paravalvular regurgitation post-transcatheter valve replacement is associated with poor outcomes. The Valve Academic Research Consortium has defined qualitative and quantitative criteria for assessing paravalvular leak severity by transthoracic echocardiography. Cardiac magnetic resonance imaging is highly accurate and reproducible in measuring aortic flow volumes, and has been used fo...
متن کاملMultimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography
Multimodality assessment of aortic stenosis severity in Transcatheter Aortic Valve Implantation (TAVI): comparison between cardiovascular magnetic resonance, transesophageal and transthoracic echocardiography Andrew Jabbour, Tevfik F Ismail, Ali Vazir, Isabelle Roussin, Ankur Gulati, Francisco Alpendurada, Sameer Zaman, Oluwatosin Sotubo, Saman S Zaman, Benjamin Hewins, Simon Davies, Sanjay K P...
متن کاملValue of CMR in quantification of paravalvular aortic regurgitation after TAVI.
AIMS To assess the value of cardiac magnetic resonance (CMR) using phase-contrast velocity mapping for paravalvular aortic regurgitation (PAR) quantification. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation (TAVI) in our centre between November 2012 and August 2013, without CMR-contraindication were included. PAR severity was assessed 5 days after TAVI usin...
متن کاملRole of Transthoracic Echocardiography in the Evaluation of Patients with Retinal Vein Occlusion
Introduction: Retinal vein occlusion is a common vascular disorder disrupting vision. Two basic types of RVO are branch retinal vein occlusion and central retinal vein occlusion (CRVO). Retinal vein occlusion is a multifactor process including systemic illness and local retinal factors.RVO may be associated with atherosclerotic risk factors. We analyzed the role of 2 dimensional transthor...
متن کاملQuantitative Analysis of Aortic Valve Stenosis and Aortic Root Dimensions by Three-Dimensional Echocardiography in Patients Scheduled for Transcutaneous Aortic Valve Implantation
Accurate assessment of the aortic valve area (AVA) and evaluation of the aortic root are important for clinical decision-making in patients being considered for transcatheter aortic valve implantation (TAVI). Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) provides accurate and reliable quantitative assessment of aortic valve stenosis and the aortic root. We performed tw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2013