High-performance liquid chromatographic determination of propofol in human plasma: comparison of different heteroscedastic calibration curve models.

نویسندگان

  • Pooria Taghavi Moghaddam
  • Mohammad Reza Pipelzadeh
  • Sholeh Nesioonpour
  • Nader Saki
  • Saeed Rezaee
چکیده

PURPOSE The aim of this study was to select the best calibration model for determination of propofol plasma concentration by high-performance liquid chromatography method. METHODS Determination of propofol in plasma after deproteinization with acetonitrile containing thymol (as internal standard) was carried out on a C18 column with a mixture of acetonitrile and trifluoroacetic acid 0.1% (60:40) as mobile phase which delivered at the flow rate of 1.2 mL/minute . Fluorescence detection was done at the excitation and emission wavelengths of 276 and 310 nm, respectively. After fitting different equations to the calibration data using weighted regression, the adequacy of models were assessed by lack-of-fit test, significance of all model parameters, adjusted coefficient of determination (R(2) adjusted) and by measuring the predictive performance with median relative prediction error and median absolute relative prediction error of the validation data set. RESULTS The best model was a linear equation without intercept with median relative prediction error and median absolute relative prediction error of 4.0 and 9.4%, respectively in the range of 10-5000 ng/mL. The method showed good accuracy and precision. CONCLUSION The presented statistical framework could be used to choose the best model for heteroscedastic calibration data for analytes like propofol with wide range of expected concentration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Advanced pharmaceutical bulletin

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2014