Simultaneous double-culprit in-stent thrombosis. Who is the guilty prisoner behind bars: drug-eluting stent, bare-metal stent, or indication for treatment?

نویسندگان

  • Giuseppe Mezzapelle
  • Roberto Baglini
  • Duccio Baldari
چکیده

BACKGROUND The intrinsic thrombogeneity of stents was the historic limitation to their usage during the early phases of stenting. The risk of stent thrombosis has been minimized by the widespread use of platelet antiaggregation. Nowadays, the risk of subacute stent thrombosis is around 1%. Thrombotic risk depends on several factors, such as type of stent, complexity of lesion, and clinical picture. CASE REPORT We present a case of recurrent acute in-stent thrombosis in a patient with mild antithrombin III (AT) deficiency despite the combined administration of clopidogrel and aspirin. CONCLUSION In our patient, several factors, such as diabetes, AT deficiency, and the use of a paclitaxel-eluting stent, have contributed to the development of recurrent acute stent thrombosis. Although we were not able to identify the culprit factor, we should keep in mind that the deployment of a drug-eluting stent could be unsafe if it is not supported by a clear clinically oriented pathway that considers the overall condition of the patient since, in some cases, neither coronary lesions nor coronary stents are responsible for the negative outcome of patient therapy, which may be caused instead by incomplete or inadequate patient assessment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Thrombosis of Two Drug-Eluting Stents After Discontinuation of Dual Antiplatelet Therapy for a Day

Stent thrombosis is rare but can lead to potential severe consequence. The incidence is relative higher in drug-eluting sent than bare-metal stent implantation. Dual antiplatelet therapy is the major treatment to avoid early and late stent thrombosis. Simultaneous two stents thrombosis is rare. Although mechanical or/and procedure factors may predispose to stent thrombosis occurred, simultaneou...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.

BACKGROUND The safety of drug-eluting stents has been called into question by recent reports of increased stent thrombosis, myocardial infarction, and death. Such studies have been inconclusive because of their insufficient size, the use of historical controls, a limited duration of follow-up, and a lack of access to original source data. METHODS We performed a pooled analysis of data from fo...

متن کامل

Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials

OBJECTIVES To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. DESIGN Mixed treatment comparison meta-analysis. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (s...

متن کامل

Comparison of a drug-eluting balloon first and then bare metal stent with a drug-eluting stent for treatment of de novo lesions: study protocol of a randomized controlled trial

BACKGROUND The use of a drug-eluting balloon for the treatment of de novo coronary artery lesions remains to be evaluated. A previous trial in patients with stable and unstable angina comparing a bare metal stent mounted on a drug-eluting balloon with a sirolimus-eluting stent failed to meet the prespecified non-inferiority criteria versus the sirolimus-eluting stent. The stent struts of a bare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cardiovascular revascularization medicine : including molecular interventions

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 2006