Coplanar versus noncoplanar intensity‐modulated radiation therapy (IMRT) and volumetric‐modulated arc therapy (VMAT) treatment planning for fronto‐temporal high‐grade glioma†

نویسندگان

  • Valerie Panet‐Raymond
  • Will Ansbacher
  • Sergei Zavgorodni
  • Bill Bendorffe
  • Alan Nichol
  • Pauline T. Truong
  • Wayne Beckham
  • Maria Vlachaki
چکیده

The purpose of this study was to compare dosimetric and radiobiological parameters of treatment plans using coplanar and noncoplanar beam arrangements in patients with fronto-temporal high-grade glioma (HGG) generated for intensity-modulated radiotherapy (IMRT) or volumetric-modulated arc therapy (VMAT). Ten cases of HGG overlapping the optic apparatus were selected. Four separate plans were created for each case: coplanar IMRT, noncoplanar IMRT (ncIMRT), VMAT, and noncoplanar VMAT (ncVMAT). The prescription dose was 60 Gy in 30 fractions. Dose-volume histograms and equivalent uniform doses (EUD) for planning target volumes (PTVs) and organs at risk (OARs) were generated. The four techniques resulted in comparable mean, minimum, maximum PTV doses, and PTV EUDs (p ≥ 0.33). The mean PTV dose and EUD averaged for all techniques were 59.98 Gy (Standard Deviation (SD) ± 0.15) and 59.86 Gy (SD ± 0.27). Non-coplanar IMRT significantly reduced contralateral anterior globe EUDs (6.7 Gy versus 8.2 Gy, p = 0.05), while both ncIMRT and ncVMAT reduced contralateral retina EUDs (16 Gy versus 18.8 Gy, p = 0.03). Noncoplanar techniques resulted in lower contralateral temporal lobe dose (22.2 Gy versus 24.7 Gy). Compared to IMRT, VMAT techniques required fewer monitor units (755 vs. 478, p ≤ 0.001) but longer optimization times. Treatment delivery times were 6.1 and 10.5 minutes for coplanar and ncIMRT versus 2.9 and 5.0 minutes for coplanar and ncVMAT. In this study, all techniques achieved comparable target coverage. Superior sparing of contralateral optic structures was seen with ncIMRT. The VMAT techniques reduced treatment delivery duration but prolonged plan optimization times, compared to IMRT techniques. Technique selection should be individualized, based on patient-specific clinical and dosimetric parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.  Material...

متن کامل

Dosimetric comparison of intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) in total scalp irradiation: a single institutional experience

PURPOSE Total scalp irradiation (TSI) is a rare but challenging indication. We previously reported that non-coplanar intensity-modulated radiotherapy (IMRT) was superior to coplanar IMRT in organ-at-risk (OAR) protection and target dose distribution. This consecutive treatment planning study compared IMRT with volumetric-modulated arc therapy (VMAT). MATERIALS AND METHODS A retrospective trea...

متن کامل

A dosimetric comparison of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer

BACKGROUND To compare dosimetric parameters of volumetric modulated arc therapy (VMAT) and non-coplanar intensity modulated radiotherapy (IMRT) for nasal cavity and paranasal sinus cancer with regard to the coverage of planning target volume (PTV) and the sparing of organs at risk (OAR). METHODS Ten patients with nasal cavity or paranasal sinus cancer were re-planned by VMAT (two-arc) plan an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012