Efficacy and Feasibility of the Submuscular Implantation Technique for an Implantable Cardiac Electrical Device
نویسندگان
چکیده
BACKGROUND A common complication associated with implantable cardiac electrical device implantation compromises skin lesions caused by overstretching just above a buried device that is relatively large in size. Apart from affecting the cosmetic appearance in some patients, a compromised blood supply to the skin may also lead to ischemic necrosis, which is an important complication. We describe a novel procedure for the implantation of implantable cardiac electrical devices generators under the pectoralis major muscle to avoid such skin-related complications. METHODS Twenty-one patients were referred to plastic surgeon for surgical support for the secondary replacement of implantable cardiac electrical devices. In all cases, the leads and devices had been implanted under the skin. We decided to perform device implantation under the pectoralis major muscle, which was highly recommended in all these patients. RESULTS In Japan, leanness is determined on the basis of body mass index less than 18.5, and 11 patients out of 21 (52%) were considered to be lean. The surgeon's participation in the procedure for implantable cardiac electrical device implantation did not exceed 5 minutes in total. CONCLUSIONS We consider that the novel method of sub-pectoralis major muscle device implantation described here minimizes the risk of the skin breakdown and improves the patient's quality of life.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملدستگاههای کاشتپذیر برای کودکان ناشنوا
The idea of providing hearing to profoundly deaf patients by artificially stimulating the sensory system has progressed from a futuristic possibility to reality. Generally, an implantable hearing device is designed to capture sound and present it to the auditory system, where at least part of the device is surgically implanted in the child receiving it. The goal of the implantable devices in yo...
متن کاملTotally submuscular implantation of subcutaneous implantable cardioverter defibrillator: a safe and effective solution for obese or oversized patients
The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a safe alternative to transvenous ICD. We describe a submuscular S-ICD placement technique in a severely obese with an oversized chest. Submuscular configuration allows optimal system positioning and impendence values warranting a safe and effective shock transmission. This technique is safe and improves patients comfort.
متن کاملImplantation of the Subcutaneous Implantable Cardioverter-Defibrillator
The subcutaneous implantable cardioverter-defibrillator (S-ICD) was introduced to reduce acute transvenous leadrelated complications, such as pneumothorax, endocarditis, cardiac perforation, and lead dislodgements, as well as the complications related to chronic indwelling leads, such as lead failure, venous obstruction, and bacteremia. The standard implantation technique of the S-ICD involves ...
متن کاملErosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2014