Comparison of zirconia and titanium implants after a short healing period. A pilot study in minipigs.

نویسندگان

  • B Stadlinger
  • M Hennig
  • U Eckelt
  • E Kuhlisch
  • R Mai
چکیده

The aim of this animal study was to investigate and compare the osseointegration of zirconia and titanium dental implants. 14 one-piece zirconia implants and 7 titanium implants were inserted into the mandibles of 7 minipigs. The zirconia implants were alternately placed submerged and non-submerged. To enable submerged healing, the supraosseous part was removed, using a diamond saw. The titanium implants were all placed submerged. After a healing period of 4 weeks, a histological analysis of the soft and hard tissue and a histomorphometric analysis of the bone-implant contact (BIC) and relative peri-implant bone-volume density (rBVD; relation to bone-volume density of the host bone) was performed. Two zirconia implants were found to be loose. All other implants were available for evaluation. For submerged zirconia and titanium implants, the implant surface showed an intimate connection to the neighbouring bone, with both types achieving a BIC of 53%. For the non-submerged zirconia implants, some crestal epithelial downgrowth could be detected, with a resultant BIC of 48%. Highest rBVD values were found for submerged zirconia (80%), followed by titanium (74%) and non-submerged zirconia (63%). The results suggest that unloaded zirconia and titanium implants osseointegrate comparably, within the healing period studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osseointegration of zirconia implants compared with titanium: an in vivo study

BACKGROUND Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface modifications have been developed to improve osseous healing. Zirconia-based implants were introduced into dental implantology as an alternative to...

متن کامل

Osseointegration of zirconia implants: an SEM observation of the bone-implant interface

BACKGROUND The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the...

متن کامل

One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study

Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, pl...

متن کامل

Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study

Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of oral and maxillofacial surgery

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 2010