Changes in MRI signal intensity during hypercapnic challenge under conscious and anesthetized conditions.
نویسندگان
چکیده
Most functional magnetic resonance imaging (fMRI) studies in animals are conducted under anesthesia to minimize motion artifacts. However, methods and techniques have been developed recently for imaging fully conscious rats. Functional MRI studies on conscious animals report enhanced BOLD signal changes as compared to the anesthetized condition. In this study, rats were exposed to different concentrations of carbon dioxide (CO(2)) while conscious and anesthetized to test whether cerebrovascular reactivity may be contributing to these enhanced BOLD signal changes. Hypercapnia produced significantly greater increases in MRI signal intensity in fully conscious animals (6.7-13.3% changes) as when anesthetized with 1% isoflurane (3.2-4.9% changes). In addition, the response to hypercapnia was more immediate in the conscious condition (< 30s) with signal risetimes twice as fast as in the anesthetized state (60s). Both cortical and subcortical brain regions showed a robust, dose- dependent increase in MRI signal intensity with hypercapnic challenge while the animals were conscious but little or no change when anesthetized. Baseline variations in MRI signal were higher while animals were conscious but this was off set by greater signal intensity changes leading to a greater contrast-to-noise ratio, 13.1 in conscious animals, as compared to 8.0 in the anesthetized condition. In summary, cerebral vasculature appears to be more sensitive to hypercapnic challenge in the conscious condition resulting in enhanced T2* MRI signal intensity and the potential for better BOLD signal changes during functional imaging.
منابع مشابه
The Relationship Between Morphology of Lumbar Disc Herniation and MRI Changes in Adjacent Vertebral Bodies
Background: Intervertebral disc herniation has two common types, extrusion and protrusion, which may affect the adjacent vertebrae.In addition, it is associated with significant signal changes in T1 MRI (short TR/TE) and T2 MRI (long TR/TE). Methods: The present study is a cross-sectional analytic one, in which sampling was performed retrospectively. Cases were randomly selected from the pa...
متن کاملEffect of Isoflurane anesthesia on BOLD response to somatosensory stimulation: results from fMRI experiments in conscious rats
INTRODUCTION: Translation of fMRI applications from preclinical to clinical experiments is confounded by the need for anesthesia in animal experiments. Anesthetic mechanisms remain poorly understood and may cause changes in cerebral metabolism, blood flow, and blood volume (CBV), which can obscure or alter the pharmacologicor sensorystimulated hemodynamic changes detected with fMRI. The complic...
متن کاملEffect of Echo Time on the Maximum Relationship between Contrast Agent Concentration and Signal Intensity Using FLAIR Sequence
Introduction Contrast-enhanced fluid-attenuated inversion recovery (FLAIR) is one of the MRI sequences that can be used for detection and evaluation of pathological changes in the brain. In this work, we have studied the effect of different echo times (TE) on the maximum relationship between signal intensity and concentration of the contrast agent using the FLAIR sequence. Materials and Methods...
متن کاملبررسی شیوع یافتههای تصویربرداری رزونانس مغناطیسی(MRI) در بیماران مبتلا به کمردرد دیسکوورتبرال دژنراتیو A STUDY OF PREVALENCE OF MRI FINDING IN PATIENTS WITH DEGENERATIVE DISCOVERTEBRAL LOW BACK PAIN
ABSTRACT Low back pain is the most common musculoskeletal disease and has a high prevalence rate in community that causes a significant morbidity, mostly due to degenerative discovertebral disease. MRI is the best and noninvasive method for assessing degenerative discovertebral disease. This study was conducted to determine MRI findings in degenerative discovertebral disease. This descri...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance imaging
دوره 21 9 شماره
صفحات -
تاریخ انتشار 2003