Ambulatory blood pressure recordings. Reproducibility and unpredictability.
نویسندگان
چکیده
The accuracy of blood pressure readings taken by the portable semiautomatic blood pressure recorder Remler M 2000 was investigated in 101 unselected, untreated volunteers. On the average, pressures recorded during usual daily activities were lower by approximately 10 mm Hg than pressures measured in the office. However, individual ambulatory pressures could not be predicted from office readings, and the difference varied among the volunteers from +14 to -43 mm Hg. The reproducibility of office and ambulatory pressures was investigated in 84 subjects. There was a highly significant correlation between pressure levels determined at a 3- to 4-month interval with both the conventional auscultatory method in the office and the Remler ambulatory recorder. These data demonstrate that the Remler M 2000 ambulatory blood pressure recorder, when used properly, provides reproducible blood pressure profiles during customary daily activities. The ambulatory pressure recorder seems particularly useful for a baseline evaluation of the usual daily blood pressure, which in the individual subject differs in a highly unpredictable manner from the blood pressure measured at the physician's office.
منابع مشابه
Factors affecting ambulatory blood pressure reproducibility. Results of the HARVEST Trial. Hypertension and Ambulatory Recording Venetia Study.
To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...
متن کاملFactors Affecting Ambulatory Blood Pressure Reproducibility Results of the HARVEST Trial
To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...
متن کاملFactors Affecting Ambulatory Blood Pressure Reproducibility
To assess the reproducibility of ambulatory blood pressure, we recorded 24-hour blood pressure twice 3 months apart in 508 hypertensive subjects participating in the HARVEST trial using a noninvasive technique. Blood pressure was measured every 10 minutes during the daytime and 30 minutes during the nighttime. Reproducibility was better for ambulatory than for office blood pressure. It was grea...
متن کاملThe reproducibility of average ambulatory, home, and clinic pressures.
The reproducibility of ambulatory, home, and clinic blood pressures was compared in 13 untreated mildly hypertensive and 14 normotensive subjects. Each subject had two sets of daily ambulatory recordings, home self-measured readings (over 6 days), and clinic measurements taken 2 weeks apart. Comparisons over the 2 weeks within and among the methods of measurements were made using a repeated-mea...
متن کاملReproducibility of ambulatory blood pressure mea- surement in patients with coronary heart disease
Ambulatory blood pressure monitoring (ABPM) is a useful tool to establish the diagnosis of hypertension as well as for the monitoring of the response to antihypertensive therapy. We aimed to assess the reproducibility of the circadian blood pressure (BP) pattern (24 h, daytime and night-time BP and heart rate HR), the categorisation of individuals as dippers and non-dippers and the morning BP p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hypertension
دوره 6 3 شماره
صفحات -
تاریخ انتشار 1984