Formaldehyde interference with the o-toluidine procedure for glucose.

نویسندگان

  • L W Bond
  • A M Savaria
  • R B McComb
چکیده

We recently noticed a significant error in the results for glucose determined by the o-toluidine method in qualitycontrol material prepared in our own laboratory. This interference was traced to one component of this control material, a uric acid stock solution containing formaldehyde. Uric acid has been reported to interfere (1, 2) and not interfere (3) in the o-toluidine procedure. The otoluidine method (4, 5 ) is based on the reaction between otoluidine and aldohexoses to form a complex mixture of colored products (6). Although this reaction is reportedly relatively specific for aldohexoses and pentoses (7-9), such statements refer to normal components of serum or urine (3, 8).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated determination of glucose in serum or plasma by a direct o-toluidine procedure.

A LDOHEXOSES REACT WITH o-toluidine in the presence of glacial acetic acid to produce a green color, which follows Beer’s law over a wide range of concentrations. This reaction is relatively selective for glucose. An improvement in manual procedures involving this reaction (1, 2) was reported by Feteris (3), who determined glucose directly on serum without deproteiization. She also improved the...

متن کامل

Method for simultaneous direct estimation of glucose and xylose in serum.

A direct procedure for measuring serum monosaccharides is presented. Borate intensifies the colors produced when these substances react with o-toluidine, which, in the case of glucose and xylose, have absorption maxima at 480 nm and 630 nm, respectively. Thus, these sugars may be determined singly or simultaneously in a single sample by differential spectrophotometry. An alternative technique i...

متن کامل

Elimination of dextran interference in serum protein determinations.

Serum containing dextrans of average molecular weight 40,000 (“Dextran-40”), 70,000 (“Dextran-70”), or 75,000 (“Dextran-75”) become turbid when biuret reagent is added (1, ). This interference has been overcome (3) by first precipitating serum proteins with trichioroacetic acid before applying the biuret reaction. Positive interference of these drugs with the o-toluidine glucose assay has also ...

متن کامل

Evaluation of a glucose oxidase-peroxidase method adapted to the single-channel autoanalyzer and SMA 12-60.

The glucose oxidase-peroxidase method for determining serum glucose, with the ammonium salt of 2,2’-azine-di (3 ethyl benzothiazoline-(6)-sulfonic acid) as the chromogen, was adapted to use with the single-channel AutoAnalyzer and the SMA 12/60 (Technicon Corp.). The extended linearity (up to 500 mg/100 ml on both systems) eliminated the need for numerous dilutions in the 300 to 500 mg/100 ml r...

متن کامل

An o-toluidine method for body-fluid glucose determination.

Featured Article: Dubowski KM. An o-toluidine method for body fluid glucose determination. Clin Chem 1962; 8:215–35. This report described a simple, rapid, and versatile method for manual measurement of glucose in whole blood, serum, cerebrospinal fluid (CSF), and other body fluids, with results fully compatible with the then–widely used automated Hoffman procedure for body-fluid glucose: reduc...