Routine operation of an Elliott 903 computer in a clinical chemistry laboratory.
نویسندگان
چکیده
Experience gained in the last four years concerning the capabilities and limitations of an 8K Elliott 903 (18-bit word) computer with magnetic tape backing store in the routine operation of a clinical chemistry laboratory is described. Designed as a total system, routine operation has latterly had to be confined to data acquisition and process control functions, due primarily to limitations imposed by the choice of hardware early in the project. In this final report of a partially successful experiment the opportunity is taken to review mistakes made, especially at the start of the project, to warn potential computer users of pitfalls to be avoided.
منابع مشابه
On-line acquisition of the output of a multi-channel analyzer (SMA 12/60) by means of an Elliott computer system.
The introduction of a multi-channel analyzer (Technicon SMA 12/60) into a laboratory, in which the outputs from single-channel, continuous flow analyzers (Technicon AA1) are acquired on-line to an Elliott 903 computer system presented an additional problem. One possible solution is discussed.
متن کاملA system for computer analysis of kinetic enzyme data from a modified Beckman DSA-560.
We define the following criteria for enzyme assays as being beyond compromise: narrow bandpass double-beam spectrophotometer, multiple readings on the sample (kinetic procedure), temperature control of assay reaction mixture to ±0.1#{176}C, wash-out between samples less than 1% of the preceding sample, and sample sizeof 100,l or less. In addition, the following specifications for a system were ...
متن کاملNecessity of Routine Repeat Testing of Critical Values in Various Working Shifts
Background & Objective: Accurate and timely reporting of critical values is an important issue. There is some doubt whether repeat testing of critical values would offer any advantage over single testing or not. The aim of this study was evaluation of utility of routine repeat testing of critical values in our referral center and to compare probable variations in different work...
متن کاملDoes routine repeat testing of critical laboratory values improve their accuracy?
Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not. Methods : We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white...
متن کاملEvaluation of a benchtop capillary gas chromatograph-mass spectrometer for clinical toxicology.
We evaluated the Hewlett-Packard 5995B benchtop capillary gas chromatograph-mass spectrometer (GC-MS) for its ability to identify drugs commonly detected and (or) measured in the clinical toxicology laboratory. Initial experiments indicated that the instrument as originally configured, with an isolation valve between the gas chromatograph and mass spectrometer, was unsatisfactory for the identi...