de Assessment of Overload Capabilities of Power Transformers by Thermal Modelling

نویسندگان

  • S. TENBOHLEN
  • R. SKRZYPEK
  • B. DOLATA
چکیده

This contribution presents an approach to determine the overload capabilities of oil-cooled power transformers depending on the ambient temperature. For this purpose the investigated method introduces a simplified, empirical based thermal model that predicts changes in oil temperature with high accuracy. This model considers the entire transformer as a single, homogenous tempered body with a certain thermal capacity. All electrical losses are perceived as an input of equally distributed heat and assumed to be the sum of the load and no-load losses given by the transformer design. In contrary to earlier approaches the heat exchange with the ambience is modelled as a complex function depending first of all on the temperature difference between the transformer and its surroundings. Furthermore, the loading rate, material properties, levels of temperatures and emerging temperature gradients are taken into account as influencing factors determining the heat exchange. To display the behaviour of a specific transformer, the model employs several empirical factors. For determination of these empirical factors an evaluation time of two to four representative weeks of transformer operation is found to be sufficient. To validate the created model and test its operational reliability, measuring data from several ONANand ONAF-transformers are consulted. These data sets comprise the top oil and ambient temperature as well as the loading rate and the status of the cooling system. Furthermore, the corresponding name plate data is integrated. Subsequently to the calculation of the top oil temperature, the maximum constant loading rate resulting in a hot-spot temperature below critical level is determined based upon the remarks of IEC 60076 7 [1]. Finally, a characteristic linear function for each investigated transformer displaying the maximum loading rate depending solely on the ambient temperature is derived. In case of the investigated ONANand ONAF-transformers within a power range of 31.5 63 MVA, significant overload potentials could be disclosed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power transformers health index calculation using reliability methods for the case study of the Dez Dam and Karkheh Dam hydro power plants

Transformers in power plants act as intermediaries between the power plant and the power grid, which are affected by electrical stresses such as switching, thermal stresses such as overload and arc, and chemical reactions in the dielectric oil. Acid and moisture components cause deterioration of transformer oil and paper insulation. Condition assessment of transformers is a method to predict an...

متن کامل

Optimal Estimation of Weibull Distribution Parameters in order to Provide Preventive-Corrective Maintenance Program for Power Transformers

In this paper, a new method for modelling and estimation of reliability parameters of power transformer components in distribution and transmission voltage levels for preventive-corrective maintenance schedule of transformers is proposed. In this method, with optimal estimation of Weibull distribution parameters using least squares method and input data uncertainty reduction, failure rate and p...

متن کامل

Reliability Analysis and Overload Capability Assessment of Oil-Immersed Power Transformers

Smart grids have been constructed so as to guarantee the security and stability of the power grid in recent years. Power transformers are a most vital component in the complicated smart grid network. Any transformer failure can cause damage of the whole power system, within which the failures caused by overloading cannot be ignored. This research gives a new insight into overload capability ass...

متن کامل

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

Condition Monitoring Techniques of Power Transformers: A Review

Power transformers provide a vital link between the generation and distribution of produced energy. Such static equipment is subjected to abuse during operation in generation and distribution stations and leads to catastrophic failures. This paper reviewed the techniques in the field of condition monitoring of power transformers in recent years. Transformer monitoring and diagnosis are the effe...