Comparison of Radiosonde and GCM Vertical Temperature Trend Profiles: Effects of Dataset Choice and Data Homogenization*

نویسندگان

  • JOHN R. LANZANTE
  • MELISSA FREE
چکیده

In comparisons of radiosonde vertical temperature trend profiles with comparable profiles derived from selected Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report (AR4) general circulation models (GCMs) driven by major external forcings of the latter part of the twentieth century, model trends exhibit a positive bias relative to radiosonde trends in the majority of cases for both time periods examined (1960–99 and 1979–99). Homogeneity adjustments made in the Radiosonde Atmospheric Temperature Products for Assessing Climate (RATPAC) and Hadley Centre Atmospheric Temperatures, version 2 (HadAT2), radiosonde datasets, which are applied by dataset developers to account for timevarying biases introduced by historical changes in instruments and measurement practices, reduce the relative bias in most cases. Although some differences were found between the two observed datasets, in general the observed trend profiles were more similar to one another than either was to the GCM profiles. In the troposphere, adjustment has a greater impact on improving agreement of the shapes of the trend profiles than on improving agreement of the layer mean trends, whereas in the stratosphere the opposite is true. Agreement between the shapes of GCM and radiosonde trend profiles is generally better in the stratosphere than the troposphere, with more complexity to the profiles in the latter than the former. In the troposphere the tropics exhibit the poorest agreement between GCM and radiosonde trend profiles, but also the largest improvement in agreement resulting from homogeneity adjustment. In the stratosphere, radiosonde trends indicate more cooling than GCMs. For the 1979–99 period, a disproportionate amount of this discrepancy arises several months after the eruption of Mount Pinatubo, at which time temperatures in the radiosonde time series cool abruptly by 0.5 K compared to those derived from GCMs, and this difference persists to the end of the record.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Radiosonde Vertical Temperature Trend Profiles: Comparing the Influence of Data Homogenization versus Model Forcings

Measurements from radiosonde temperatures have been used in studies that seek to identify the human influence on climate. However, such measurements are known to be contaminated by artificial inhomogeneities introduced by changes in instruments and recording practices that have occurred over time. Some simple diagnostics are used to compare vertical profiles of temperature trends from the obser...

متن کامل

Trends in Tropospheric Humidity from 1970 to 2008 over China from a Homogenized Radiosonde Dataset

Radiosonde humidity data provide the longest record for assessing changes in atmospheric water vapor, but they often contain large discontinuities because of changes in instrumentation and observational practices. In this study, the variations and trends in tropospheric humidity (up to 300 hPa) over China are analyzed using a newly homogenized radiosonde dataset. It is shown that the homogeniza...

متن کامل

Temporal Homogenization of Monthly Radiosonde Temperature Data. Part II: Trends, Sensitivities, and MSU Comparison

Trends in radiosonde-based temperatures and lower-tropospheric lapse rates are presented for the time periods 1959–97 and 1979–97, including their vertical, horizontal, and seasonal variations. A novel aspect is that estimates are made globally of the effects of artificial (instrumental or procedural) changes on the derived trends using data homogenization procedures introduced in a companion p...

متن کامل

Estimation of temperature and humidity from MST radar observations

Retrieval of vertical profiles of temperature and humidity parameters using a VHF radar is described in this paper. For this, Indian MST radar located at Gadanki (13.5◦ N, 79.2◦ E) has been operated in a special mode. First, vertical velocities are collected continuously using the radar and are subjected to Fast Fourier Transform (FFT) analysis to obtain Brunt-Väisälä oscillations. From the mea...

متن کامل

بررسی آلودگی هوای شهر تهران به روش وارونگی بحرانی هافتر

In issues related to air pollution, the thickness of the boundary layer is known as the depth of the mixed layer because the pollution on the ground surface is mixed in this entire layer through turbulence processes. In most cases, the boundary of the area is clearly visible on big industrial cities. The depth of the mixed layer has an important effect in the concentration of air pollution whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -