Design of Delta Primary - Transposed zigzag Secondary (DTz) Transformer to Minimize Harmonic Currents on the Three-phase Electric Power Distribution System

نویسندگان

  • Chairul Gagarin Irianto
  • Rudy Setiabudy
  • Chairul Hudaya
چکیده

The delta primary transposed zigzag secondary (DTz) transformer has been designed and used to reduce the bad impacts of the harmonic in the distribution power system. The DTz transformer is constructed with delta connection in primary winding and the three transposed windings at the different core legs of secondary winding. The harmonic reduction method of the DTz transformer applies two basic principles. The first principle is to inhibit electromagnetic energy of the harmonic currents by cancelling the phase polarity on the secondary winding. The second is to insulate the remaining of the mmf induction from harmonic current loads and minimize to circulate in the delta windings on the primary side. The triplen harmonics currents generated on the primary and secondary winding of DTz transformer are simulated in this paper. Both balanced and unbalanced loads of the three-phase distribution system are examined. The experiment shows that the total THD current in the secondary winding when balanced loads are applied is about 70.8 %, and in the primary side is 24.3 %. While for unbalanced loads, the average THD in secondary winding is 68.44 % and in delta winding is 26.4 %. It means the DTz transformer has a filter-ability to reduce about 42 46 % THD for both balanced and unbalanced loads. By comparing the computer simulation results and data measurements through experiment in the laboratory, it is proved that the use of the proposed DTz transformer is one of the methods to reduce harmonic currents and inhibit them to enter to the supply system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THD Mitigation in Line Currents of 6-Pulse Diode Bridge Rectifier Using the Delta-Wye Transformer as a Triplen Harmonic Filter

The uncontrolled three-phase bridge rectifier has the least line current distortion among six-pulse rectifiers; however, its total harmonic distortion (THD) of 31.08% is unacceptable as per the contemporary power quality standards. This paper seeks to address the issue by elimination of triplen harmonics in the line currents by providing a deltawye transformer at the ac interface i.e. between t...

متن کامل

Neuro-fuzzy Based Power Quality Improvements in a Three Phase Four Wire Distribution System Using Dstatcom Neuro-fuzzy Based Power Quality Improvements in a Three Phase Four Wire Distribution System Using Dstatcom

This project presents reactive power compensation in a distribution power system. DSTATCOM (distribution static compensator) is a reactive power compensator for power quality improvement in a three phase four wire distribution system. A voltage source converter (VSC) based DSTATCOM with a zig-zag transformer is used for the compensation of reactive power for voltage regulation along with load b...

متن کامل

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace

The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...

متن کامل

The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace

The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010