Impact of contralateral and ipsilateral reference tissue selection on self-referencing differential spectroscopy for breast cancer detection.

نویسندگان

  • Anaïs Leproux
  • Albert E Cerussi
  • Wendy Tanamai
  • Amanda F Durkin
  • Montana Compton
  • Enrico Gratton
  • Bruce J Tromberg
چکیده

We previously developed a self-referencing differential spectroscopic (SRDS) method to detect lesions by identifying a spectroscopic biomarker of breast cancer, i.e., the specific tumor component (STC). The SRDS method is based on the assumption of the exclusive presence of this spectroscopic biomaker in malignant disease. Although clinical results using this method have already been published, the dependence of the STC spectra on the choice of reference tissue has not yet been addressed. In this study, we explore the impact of the selection of the reference region size and location on the STC spectrum in 10 subjects with malignant breast tumors. Referencing from both contralateral and ipsilateral sides was performed. Regardless of the referencing, we are able to obtain consistent high contrast images of malignant lesions using the STC with less than 13% deviation. These results suggest that the STC measurements are independent of any type, location, and amount of normal breast tissue used for referencing. This confirms the initial assumption of the SRDS analysis, that there are specific tumor components in cancer that do not exist in normal tissue. This also indicates that bilateral measurements are not required for lesion identification using the STC method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

Optimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy

Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...

متن کامل

Designing a shield to reduce radiation dose during mammography: Dosimetric evaluation

Background: This paper presents a method to reduce radiation exposure during mammography by analysing the doses to ipsilateral and contralateral breasts and to adjacent organs by evaluating material-dependent shielding performance.  Materials and Methods: Six target-filter combinations (Mo-Mo, Mo-Rh, Rh-Rh, Rh-Mo, W-Mo, W-Rh) were tested by measuring the doses delivered to the breasts and adjac...

متن کامل

The Relationship between Breast Self-examination and the Disease Stage in Detection Time among Patients with Breast Cancer in Yazd

Introduction: breast cancer, as the most common cancer among women, is controllable if it is diagnosed at the early stages. Breast self- examination is a simple method for early detection. One of the most important effective factors on the cancer-related mortality is the defection stage. This study was conducted to determine the relationship between breast self-examination and the disease stage...

متن کامل

Effect of uniform magnetic field on dose distribution in the breast radiotherapy

Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...