Energy storage and release of prosthetic feet. Part 1: Biomechanical analysis related to user benefits.
نویسندگان
چکیده
The energy storing and releasing behaviour of 2 energy storing feet (ESF) and 2 conventional prosthetic feet (CF) were compared (ESF: Otto Bock Dynamic Pro and Hanger Quantum; CF: Otto Bock Multi Axial and Otto Bock Lager). Ten trans-tibial amputees were selected. The study was designed as a double-blind, randomised trial. For gait analysis a VICON motion analysis system was used with 2 AMTI force platforms. A special measuring device was used for measuring energy storage and release of the foot during a simulated step. The impulses of the anteroposterior component of the ground force showed small, statistically non-significant differences (deceleration phase: 22.7-23.4 Ns; acceleration phase: 17.0-18.4 Ns). The power storage and release phases as well as the net results also showed small differences (maximum difference in net result is 0.03 J kg-1). It was estimated that these differences lead to a maximum saving of 3% of metabolic energy during walking. It was considered unlikely that the subjects would notice this difference. It was concluded that during walking differences in mechanical energy expenditure of this magnitude are probably not of clinical relevance. Ankle power, as an indicator for energy storage and release gave different results to the energy storage and release as measured with the special test device, especially during landing response. In the biomechanical model (based on inverse dynamics) used in the gait analysis the deformation of the material is not taken into consideration and hence this method of gait analysis is probably not suitable for calculation of shock absorption.
منابع مشابه
Energy storage and return prostheses: does patient perception correlate with biomechanical analysis?
The development and prescription of energy storage and return prosthetic feet in favor of conventional feet is largely based upon prosthetist and amputee experience. Regretfully, the comparative biomechanical analysis of energy storage and return and conventional prosthetic feet is rarely a motivation to either the technical development or clinical prescription of such devices. The development ...
متن کاملEnergy storage and release of prosthetic feet
This paper is the second part of a study on biomechanical and functional properties of prosthetic feet. The first part dealt with a biomechanical analysis related to user benefits. This part deals with subjective ratings and deciding factors for trans-tibia] amputees using 2 energy storing feet (ESF) and 2 conventional feet (CF). The Otto Bock Dynamic Pro and Hanger Quantum feet were used as ES...
متن کاملClinical Relevance for the Veteran
Purpose of the Work. The review examines techniques of performance analysis in energy storage and return (ESAR) prosthetic feet, synthesizes clinical study results reported in the literature, suggests a technically accurate and common terminology, and proposes a novel method of foot classification for use in prosthetic research, design, and prescription. Procedures. An array of techniques has b...
متن کاملThe influence of energy storage and return foot stiffness on walking mechanics and muscle activity in below-knee amputees.
BACKGROUND Below-knee amputees commonly experience asymmetrical gait patterns and develop comorbidities in their intact and residual legs. Carbon fiber prosthetic feet have been developed to minimize these asymmetries by utilizing elastic energy storage and return to provide body support, forward propulsion and leg swing initiation. However, how prosthetic foot stiffness influences walking char...
متن کاملAnalysis of Rollover Shape and Energy Storage and Return in Cantilever Beam-type Prosthetic Feet
This paper presents an analysis of the rollover shape and energy storage and return in a prosthetic foot made from a compliant cantilevered beam. The rollover shape of a prosthetic foot is defined as the path of the center of pressure along the bottom of the foot during stance phase of gait, from heel strike to toe off. This path is rotated into the reference frame of the ankle-knee segment of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Prosthetics and orthotics international
دوره 21 1 شماره
صفحات -
تاریخ انتشار 1997