Simultaneous Observations with Three FTSs

نویسندگان

  • D. Wunch
  • J. R. Taylor
  • D. Fu
  • P. Bernath
  • J. R. Drummond
  • C. Midwinter
  • K. A. Walker
چکیده

Simultaneous ground-based observations of O3, HCl, N2O, and CH4 over Toronto, Canada by three Fourier transform spectrometers with different resolutions D. Wunch, J. R. Taylor, D. Fu, P. Bernath, J. R. Drummond, C. Midwinter, K. Strong, and K. A. Walker Department of Physics, University of Toronto, Toronto, ON, M5S 1A7, Canada Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada Department of Chemistry, University of York, Heslington, York, YO10 5DD, UK Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, B3H 3J5, Canada Received: 19 September 2006 – Accepted: 19 October 2006 – Published: 26 October 2006 Correspondence to: D. Wunch ([email protected])

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous ground-based observations of O3, HCl, N2O, and CH4 over Toronto, Canada by three Fourier transform spectrometers with different resolutions

An intercomparison of three Fourier transform spectrometers (FTSs) with significantly different resolutions is presented. The highest-resolution instrument has a maximum optical path difference of 250 cm, and the two lowerresolution instruments have maximum optical path differences of 50 cm and 25 cm. The results indicate that the two lower-resolution instruments can retrieve total column amoun...

متن کامل

Testing flow-through air samplers for use in near-field vapour drift studies by measuring pyrimethanil in air after spraying.

Pesticide volatilisation and subsequent vapour drift reduce a pesticide's efficiency and contribute to environmental contamination. High-volume air samplers (HVSs) are often used to measure pesticide concentrations in air but these samplers are expensive to purchase and require network electricity, limiting the number and type of sites where they can be deployed. The flow-through sampler (FTS) ...

متن کامل

Dynamic FTSS in Asynchronous Systems: the Case of Unison

Distributed fault-tolerance can mask the effect of a limited number of permanent faults, while self-stabilization provides forward recovery after an arbitrary number of transient fault hit the system. FTSS protocols combine the best of both worlds since they are simultaneously fault-tolerant and self-stabilizing. To date, FTSS solutions either consider static (i.e. fixed point) tasks, or assume...

متن کامل

Classification of frailty and falls history using a combination of sensor-based mobility assessments.

Frailty is an important geriatric syndrome strongly linked to falls risk as well as increased mortality and morbidity. Taken alone, falls are the most common cause of injury and hospitalization and one of the principal causes of death and disability in older adults worldwide. Reliable determination of older adults' frailty state in concert with their falls risk could lead to targeted interventi...

متن کامل

An Experimental Study of Incentive Reversal in Sequential and Simultaneous Games

I t is commonly held that increasing monetary rewards enhance work effort. This study, however, argues that this will not ineludibly occur in team activities. Incentive Reversal may occur in sequential team productions featuring positive external impacts on agents. This seemingly paradoxical event is explained through two experiments in this article. The first experiment involves a sample ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006