The accuracy and reliability of commercial heart rate monitors.
نویسندگان
چکیده
In recent years increasing emphasis has been placed on the benefits of exercise to normal healthy adults as well as to those recovering from heart attacks and other illnesses. As an aid to exercise training many portable heart-rate monitors have been placed on the market but little appears to have been done to assess the performance of these machines. The authors have examined the performance of four such monitors both under bench-test and practical exercising conditions. When tested on the bench using electronic equipment, the machines rarely exhibited errors exceeding 2-3 bpm over a measurement range of 30-240 bpm. However, when tested with subjects walking or jogging at low speeds on a treadmill, typically 20-70% of the readings given by the machines had errors of greater than 20 bpm. In some cases over 50% of readings had errors exceeding 50 bpm.
منابع مشابه
Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors
Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...
متن کاملCan the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?
Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...
متن کاملThe comparison of growth, survival rate and behavior of Oscar fish (Astronauts ocellatus) fries fed by Artemia urmiana, earthworm and beef heart supplemented diets
This study was conducted to evaluate the effect of different fresh feed supplemented to commercial diet on growth and survival of Oscar fish (Astronauts ocellatus) (initial weight: 1.58-1.70 g) during 60-day period. The husbandry environment consisted of glass aquariums appropriate to growth with a photoperiod cycle of 12 L: 12 D. The water temperature was kept at 28 ±1°C. 360 fries of Oscar (i...
متن کاملOn Reliability of Android Wearable Health Devices
Wearable devices are increasingly being used for monitoring health signals and for fitness purposes with typical uses being calorie tracker, workout assistant, and step counter. Even though these wearables can measure many health signals (e.g. heart rate), they are still not perceived as highly accurate, relative to clinical monitoring devices. In this paper, we investigate the accuracy of hear...
متن کاملImproving the Periodicity Measurement in Fetal Heart Activity Signal
In this paper we discussed the influence of preliminary processing of the ultrasound Doppler signal on accuracy of the fetal heart rate estimation as well as on reliability of the FHR instantaneous variability assessment. We attempted to develop an optimal processing channel of US Doppler signal in order to measure the periodicity of fetal heart activity with accuracy as close as possible to th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of sports medicine
دوره 21 1 شماره
صفحات -
تاریخ انتشار 1987