Characterization and diurnal variation of size-resolved inorganic water-soluble ions at a rural background site.

نویسندگان

  • Rita Ocskay
  • Imre Salma
  • Wan Wang
  • Willy Maenhaut
چکیده

Water-soluble inorganic ions in aerosol samples have been studied. The sample collection took place during summer in 2003 at a European background site which is operating within the framework of the European Monitoring and Evaluation Program. Gent type PM10 stacked filter unit (SFU) samplers were operated in parallel on a day and night basis to collect particles in separate coarse (2.0-10 microm) and fine (<2.0 microm) size fractions. Particulate masses were measured gravimetrically; the filters from one of the SFU samplers were analyzed by particle-induced X-ray emission spectrometry (PIXE) and instrumental neutron activation analysis (INAA). Filters from the other SFU sampler were analyzed by ion chromatography (IC) for major inorganic anions (MSA-, NO2(-), NO3(-), Cl-, Br-, SO4(2-), oxalate) and cations (Na+, K+, NH4(+), Mg2+, Ca2+). The water-soluble inorganic ions measured were responsible for 44% and 16% of the total fine and coarse particulate mass, respectively. In the fine size fraction, the main ionic components were SO4(2-) and NH4(+) accounting for about 90% of fine ionic mass. In the coarse fraction the main ionic components were Ca2+ and NO3(-), followed by SO4(2-). Significant day and night difference in the mass concentrations was observed only for fine NO3(-). The molar ratios of fine NH4(+) to SO4(2-) indicated their complete neutralization to (NH4)2SO4. According to the cation-to-anion ratios the coarse particles were alkaline, while the fine particles were slightly acidic or neutral. By comparing the corresponding concentrations obtained from PIXE/INAA and IC, we determined the water-extractable part of the individual species. We also investigated the effect of long-range transported air masses on the local air concentrations, and we found that the air quality of this background monitoring station was affected by regional pollution sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation and application of a semi-continuous chemical characterization system for water soluble inorganic PM2.5 and associated precursor gases

Water soluble inorganic particles components (Cl, SO 4 , NO − 3 , and NH + 4 ) and concentrations of their associated precursor gases (HCl, SO2, HNO3, NH3) were semi-continuously measured using the Dionex Gas Particle Ion Chromatography (GPIC) system. Sampling was conducted adjacent to a high traffic street in downtown Toronto, Canada from June 2006 to March 2007. This study evaluated the preci...

متن کامل

Redox activity and chemical speciation of size fractioned PM in the communities of the Los Angeles – Long Beach Harbor

In this study, two different types of assays were used to quantitatively measure the re-dox activity of PM and to examine its intrinsic toxicity: 1) in vitro exposure to rat alveolar macrophage (AM) cells using dichlorofluorescin diacetate (DCFH-DA) as the fluorescent probe (macrophage ROS assay), and: 2) consumption of dithiothreitol (DTT) in 5 a cell-free system (DTT assay). Coarse (PM 10−2.5...

متن کامل

Seasonal and diurnal characteristics of water soluble inorganic compounds in the gas and aerosol phase in the Zurich area

Gas and aerosol samples were taken using a wet effluent diffusion denuder/aerosol collector (WEDD/AC) coupled to ion chromatography (IC) in the city of Zurich, Switzerland from August to September 2002 and in March 2003. The water soluble inorganic anions nitrate, sulfate, and nitrite were analyzed online with a time resolution of two hours for the gas and aerosol phase. The fraction of water s...

متن کامل

محتوای یونی و منابع انتشار احتمالی ذرات معلق هوای شهر تبریز در سال 93-92

Background and Objective: The present study was carried out to determine the amount and ionic characterization of TSP and PM10 aimed at identifying  the potential emission sources of particulates in the ambient air of Tabriz. Materials and Methods: TSP and PM10 samples were collected by two high volume samplers during September 2013 to August 2014. Water-soluble ions in particulate matter we...

متن کامل

Cloud condensation nuclei activity at Jeju Island, Korea in spring 2005

We measured the number concentrations of cloud condensation nuclei (CCN) and the size distributions of CCN/CN (CN: condensation nuclei) ratios at supersaturations (SSs) of 0.097, 0.27, 0.58, and 0.97% at Jeju Island, Korea during March-April 2005. We made simultaneous measurements of aerosol inorganic ions, water-soluble organic carbon (WSOC), organic carbon (OC), and elemental carbon (EC) in P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental monitoring : JEM

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2006