New murmurs in patients with prosthetic heart valves.

نویسندگان

  • N A Cromie
  • S J Walsh
  • A A M Ahmed
  • G Campalani
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

Patients' observations of bioprosthetic valve failure: "my heart is honking, doctor".

Audible cardiac murmurs are uncommon and may indicate severe native valve dysfunction. In six patients with bioprosthetic mitral valves audible honking systolic murmurs suddenly developed. Doppler echocardiography showed characteristic striated regurgitant signals. At operation each prosthesis had torn cusps. New audible murmurs and striated Doppler signals originating from mitral bioprosthetic...

متن کامل

A survey on the prevalence of heart murmurs in polo horses

Background: Cardiac murmur and subsequently cardiac failure is one of the poor-performance causes in athletic horses. Attention to murmur character is vital during heart examination. Polo is a sport which demands very high stress on horses, which may result in more stress on cardiovascular system. Objectives: In this study we assume that high pressure on polo horses makes them more susceptible ...

متن کامل

Clinical significance of multiple systolic clicks from Starr-Edwards prosthetic aortic valves.

The use of echocardiography, phonocardiography, and spectroanalysis has enhanced the ability to detect prosthetic valve dysfunction even before the onset of symptoms in many patients. Reduction in the intensity of the opening and closing clicks and the appearance of new murmurs have been the most frequently reported observations in predicting prosthetic valve dysfunction. Simultaneous echocardi...

متن کامل

Noninvasive evaluation of normal and abnormal prosthetic valve function.

Noninvasive techniques are helpful in evaluating the function of mechanical prostheses and tissue valves. Combined phonocardiography and M-mode echocardiography together with cinefluoroscopy are the most useful noninvasive techniques in differentiating normal from abnormal metallic prosthetic valve function. The intensity of the opening and closing clicks and associated murmurs will depend on t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Postgraduate medical journal

دوره 79 934  شماره 

صفحات  -

تاریخ انتشار 2003