The subresolution DaTSCAN phantom: a cost-effective, flexible alternative to traditional phantom technology

نویسندگان

  • Jonathan C. Taylor
  • Nicholas Vennart
  • Ian Negus
  • Robin Holmes
  • Oliver Bandmann
  • Christine Lo
  • John Fenner
چکیده

The Alderson striatal phantom is frequently used to assess I-FP-CIT (Ioflupane) image quality and to test semi-quantification software. However, its design is associated with a number of limitations, in particular: unrealistic image appearances and inflexibility. A new physical phantom approach is proposed on the basis of subresolution phantom technology. The design incorporates thin slabs of attenuating material generated through additive manufacturing, and paper sheets with radioactive ink patterns printed on their surface, created with a conventional inkjet printer. The paper sheets and attenuating slabs are interleaved before scanning. Use of thin layers ensures that they cannot be individually resolved on reconstructed images. An investigation was carried out to demonstrate the performance of such a phantom in producing simplified I-FP-CIT uptake patterns. Single photon emission computed tomography imaging was carried out on an assembled phantom designed to mimic a healthy patient. Striatal binding ratio results and linear striatal dimensions were calculated from the reconstructed data and compared with that of 22 clinical patients without evidence of Parkinsonian syndrome, determined from clinical follow-up. Striatal binding ratio results for the fully assembled phantom were: 3.1, 3.3, 2.9 and 2.6 for the right caudate, left caudate, right putamen and right caudate, respectively. All were within two SDs of results derived from a cohort of clinical patients. Medial-lateral and anterior-posterior dimensions of the simulated striata were also within the range of values seen in clinical data. This work provides the foundation for the generation of a range of more clinically realistic, physical phantoms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

یک فانتوم سر ریاضیاتی برای بررسی‌های دوزیمتری به روش مونت‌کارلو

Introduction: In diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. Monte Carlo methods are used due to the high complexity and cost of patient-specific phantom construction. The high complexity of the digitized phantoms greatly increases the time and computational task of the Monte Carlo calculati...

متن کامل

Gelatin Phantom

For determining the absorbed dose of ionizing radiation is tissues, it is essential to have materials which behave like tissues. These kinds of materials are usually called phantom. Up to now many different compounds like water, rubber, Perspex etc have been used. Unfortunately, the practical use of each of them has had its own problems. Our suggested gelatin phantom is very similar to soft...

متن کامل

Design and Development of an Indigenous in-house Tissue-Equivalent Female Pelvic Phantom for Radiological Dosimetric Applications

Introduction: The present study is aimed to design and develop a tissue-equivalent pelvic phantom, mimicking the Indian female pelvic dimensions by means of locally available and cost-effective tissue substitutes having equivalent radiological properties. Materials and Methods: For the purpose of the study, the real female pelvic bones were embedded for preparation. Paraffin wax, Aloe-vera powd...

متن کامل

Evaluation of a constructed head phantom response in comparison with RANDO head phantom in the same gamma field

Human tissue equivalent phantoms are widely used in medicine. They are used for dosimetry, calibration of medical devices, and quality control of radiotherapy equipment, as well as training students. Regarding to development of radiotherapy techniques for treatment of cancers and also development of educational centers in the country, the human equivalent phantoms are needed. Several phantoms h...

متن کامل

The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification

Purpose. Striatal single photon emission computed tomography (SPECT) imaging of the dopaminergic system is becoming increasingly used for clinical and research studies. The question about the value of nonuniform attenuation correction has become more relevant with the increasing availability of hybrid SPECT-CT scanners. In this study, the value of nonuniform attenuation correction and correctio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 39  شماره 

صفحات  -

تاریخ انتشار 2018