Safety of metallic implants in magnetic resonance imaging.

نویسنده

  • H S Ho
چکیده

Magnetic resonance (MR) imaging has become a commonly accepted medical procedure. Manufacturers of medical implant devices are submitting claims that their devices are safe and effective in a MR environment. This paper concentrates on the issue of heating of patients due to the interaction of metallic implants with the strong radiofrequency (RF) magnetic field produced by the MR scanner. The commercially available program XFDTD was used to calculate the specific absorption rate (SAR) distribution in a realistic model of the human body. The body contained a metallic implant and was exposed to RF magnetic fields at 64 MHz from a model of a MR birdcage body coil. The results of the calculation showed that the magnitude of the increased heating of tissues due to the presence of the metallic implant depended on the dimensions, orientation, shape, and location of the metallic implant in the patient. This increased heating of surrounding tissues primarily concentrates in a small volume near the tip of the metallic wire. When the whole-body SAR was normalized to 1 W/kg, a calculated value of 41 W/kg was obtained at this location if the absorption was averaged over 1 g of tissue. However, a maximum value of 310 W/kg was calculated when the absorption was averaged over 1/8 g of tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance safety update 2002: implants and devices.

The preservation of a safe magnetic resonance (MR) environment requires constant vigilance by MR healthcare professionals, particularly with regard to the management of patients with metallic biomedical implants or devices. The variety and complexity of implants and devices constantly changes, requiring continuous attention and diligence with regard to obtaining the most current and accurate in...

متن کامل

[Development of an magnetic resonance imaging safety management system for metallic biomedical products using an magnetic resonance compatibility database and inquiry-based patient records].

Several incidents involving magnetic resonance imaging (MRI) examinations of patients with unchecked MR-unsafe metallic products have been reported. To improve patient safety, we developed a new MRI safety management system for metallic biomedical products and evaluated its efficiency in clinical practice. Our system was integrated into the picture archiving and communication system (PACS) and ...

متن کامل

Use of Magnetic Resonance Imaging in Food Quality Control: A Review

Modern challenges of food science require a new understanding of the determinants of food quality and safety. Application of advanced imaging modalities such as magnetic resonance imaging (MRI) has seen impressive successes and fast growth over the past decade. Since MRI does not have any harmful ionizing radiation, it can be considered as a magnificent tool for the quality control of food prod...

متن کامل

Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...

متن کامل

The effect of nuclear magnetic resonance imaging on metallic middle ear prostheses.

Nuclear magnetic resonance imaging, a relatively new diagnostic instrument, is a noninvasive imaging method which, among its many advantages, uses no ionizing radiation. There are a few limitations and contraindications to its use. There may be displacement of intracerebral aneurysm clips and metallic implants, and cardiac pacemakers can be disabled because of the high magnetic field created by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2001