Normal Laboratory Reference Intervals among Healthy Adults Screened for a HIV Pre-Exposure Prophylaxis Clinical Trial in Botswana

نویسندگان

  • Tebogo M. Segolodi
  • Faith L. Henderson
  • Charles E. Rose
  • Kyle T. Turner
  • Clement Zeh
  • Peter N. Fonjungo
  • Richard Niska
  • Clyde Hart
  • Lynn A. Paxton
چکیده

INTRODUCTION Accurate clinical laboratory reference values derived from a local or regional population base are required to correctly interpret laboratory results. In Botswana, most reference intervals used to date are not standardized across clinical laboratories and are based on values derived from populations in the United States or Western Europe. METHODS We measured 14 hematologic and biochemical parameters of healthy young adults screened for participation in the Botswana HIV Pre-exposure Prophylaxis Study using tenofovir disoproxil fumarate and emtricitabine (TDF/FTC) (TDF2 Study). Reference intervals were calculated using standard methods, stratified by gender, and compared with the site-derived reference values used for the TDF2 study (BOTUSA ranges), the Division of AIDS (DAIDS) Grading Table for Adverse Events, the Botswana public health laboratories, and other regional references. RESULTS Out of 2533 screened participants, 1786 met eligibility criteria for participation in study and were included in the analysis. Our reference values were comparable to those of the Botswana public health system except for amylase, blood urea nitrogen (BUN), phosphate, total and direct bilirubin. Compared to our reference values, BOTUSA reference ranges would have classified participants as out of range for some analytes, with amylase (50.8%) and creatinine (32.0%) producing the highest out of range values. Applying the DAIDS toxicity grading system to the values would have resulted in 45 and 18 participants as having severe or life threatening values for amylase and hemoglobin, respectively. CONCLUSION Our reference values illustrate the differences in hematological and biochemical analyte ranges between African and Western populations. Thus, the use of western-derived reference laboratory values to screen a group of Batswana adults resulted in many healthy people being classified as having out-of-range blood analytes. The need to establish accurate local or regional reference values is apparent and we hope our results can be used to that end in Botswana.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunohaematological reference values for HIV-negative healthy adults in Botswana

BACKGROUND Clinical laboratories in Botswana have relied entirely on the reference intervals for normal immunohaematological values provided by manufacturers' kits and textbooks. OBJECTIVES The aim of this study was to determine the means, medians, 2.5th and 97.5th percentile reference intervals, for normal immunohaematological values in healthy adults in Botswana. METHOD A total of 261 hea...

متن کامل

Reference Values of Lymphocyte Sub-Populations in Healthy Human Immunodeficiency Virus-Negative Iranian Adults

Background: Lymphocyte subsets enumeration is considered prominent in the management of primary and acquired immunodeficiency disorders. Because of local variations due to race, age, gender, and environmental conditions on lymphocyte subsets, and to improve the accuracy of interpretation of laboratory findings, reference intervals must be determined in every population. Objective: To establish ...

متن کامل

Bone Mineral Density Changes among HIV-Uninfected Young Adults in a Randomised Trial of Pre-Exposure Prophylaxis with Tenofovir-Emtricitabine or Placebo in Botswana

BACKGROUND Tenofovir-emtricitabine (TDF-FTC) pre-exposure prophylaxis (PrEP) has been found to be effective for prevention of HIV infection in several clinical trials. Two studies of TDF PrEP among men who have sex with men showed slight bone mineral density (BMD) loss. We investigated the effect of TDF and the interaction of TDF and hormonal contraception on BMD among HIV-uninfected African me...

متن کامل

Evaluation of Locally Established Reference Intervals for Hematology and Biochemistry Parameters in Western Kenya

BACKGROUND Important differences have been demonstrated in laboratory parameters from healthy persons in different geographical regions and populations, mostly driven by a combination of genetic, demographic, nutritional, and environmental factors. Despite this, European and North American derived laboratory reference intervals are used in African countries for patient management, clinical tria...

متن کامل

Verification of chemistry reference ranges using a simple method in sub-Saharan Africa

BACKGROUND Chemistry safety assessments are interpreted by using chemistry reference ranges (CRRs). Verification of CRRs is time consuming and often requires a statistical background. OBJECTIVES We report on an easy and cost-saving method to verify CRRs. METHODS Using a former method introduced by Sigma Diagnostics, three study sites in sub-Saharan Africa, Bondo, Kenya, and Pretoria and Blo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014