Is tension band wiring technique the "gold standard" for the treatment of olecranon fractures? A long term functional outcome study
نویسندگان
چکیده
BACKGROUND Tension band wiring (TBW) remains the most common operative technique for the internal fixation of olecranon fractures despite the potential occurrence of subjective complaints due to subcutaneous position of the hardware. Aim of this long term retrospective study was to evaluate the elbow function and the patient-rated outcome after TBW fixation of olecranon fractures. METHODS We reviewed 62 patients (33 men and 29 women) with an average age of 48.6 years (range, 18-85 years) who underwent TBW osteosynthesis for isolated olecranon fractures. All patients were assessed both clinically with measurement of flexion-extension and pronation-supination arcs and radiologically with elbow X-Rays. Functional outcome was estimated using the Mayo Elbow Performance Score (MEPS), Visual Analogue Scale (VAS) subjective pain score and VAS patient satisfaction score. Follow up: 6-13 years (average 8.2 years). RESULTS There was a higher prevalence of fractures among men until the 5th decade of life and among women in elderly (p = 0.032). Slip or simple fall onto the arm was the main mechanism of injury for 38 fractures (61.3%) while high energy trauma, such as fall from a height (> 2 m) or road accident, was reported in 24 fractures (38.7%). Hardware removal performed in 51 patients (82.3%) but 34 of them (66.6% of removals) were still complaining for mild pain during daily activities. The incidence of pin migration and loosening was not statistically decreased when penetration of the anterior ulnar cortex was accomplished (p = 0.304). Supination was more often affected than pronation (p = 0.027). According to MEPS, 53 patients (85.5%) had a good to excellent result, 6 (9.7%) fair and 3 (4.8%) poor result. The average satisfaction rating was 9.3 out of 10 (range, 6-10) with 31 patients (50%) to remain completely satisfied from the final result. Degenerative changes recorded in 30 elbows (48.4%). However, no correlation could be found between radiographic findings and MEPS (p = 0.073). CONCLUSION Tension band wiring fixation remains the "gold standard" for the treatment of displaced and minimally comminuted olecranon fractures. In long term, low levels of pain may be evident regardless of whether the metalware is removed and degenerative changes have been developed.
منابع مشابه
Modified Tension Band Wiring in Adult Distal Humeral Fracture Types A2 and C1
Background: Distal humeral fractures accounts for approximately 2% of all fractures and nearly one-third of humeralfractures in adults. In this regard, Modified Tension Bind Wiring (MTBW) technique was used for the fixation of the distalhumeral fractures type A2 and C1 (AO) to evaluate the early movement and complications of the patients.Methods: This study was conducted on 25...
متن کاملA Prospective Randomised Control Trial for Comparison Between olecranon Lock Plate And Tension Band Wiring In Transverse olecranon Fractures
Introduction: Olecranon fractures are frequently encountered in the practice of orthopaedic surgery with a prevalence of 60% among patients with a fracture of the proximal ulna. Generally the treatment of choice for displaced olecranon fracture is open reduction and internal fixation. We report the result of a prospective Randomised Control Trial of Forty patients, who were treated either by Te...
متن کاملOperative treatment of communited olecranon fractures using tension-band wiring and miniplate augmentation.
Olecranon fractures are intra-articular injuries that require anatomic restoration of the articular surface. For most simple noncomminuted transverse olecranon fractures, tension band wire fixation can provide a stable construct to allow for early joint range of motion. However, in comminuted olecranon fractures, it is difficult to provide a sufficient buttress for impacted articular fragments ...
متن کاملComparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures.
Aim of the present study was to compare the clinical and radiographic outcome of tension band wiring and precontoured locking compression plate fixation in patients treated surgically for an isolated olecranon fractures type IIA according to the Mayo classification. Of 26 patients presenting with an isolated Mayo type IIA olecranon fracture, 13 underwent fixation with a precontoured locking com...
متن کاملOlecranon Process Fracture in a Radial Club Hand Treated with Tension Band Wiring: A Case Report
INTRODUCTION Radial club hand is rare deformity, and many patients do not receive treatment due to lack of awareness. None of the treatment options available can restore normality. Fractures of the olecranon process in radial club hand are rare probably due to limited use of the limb. CASE REPORT We report the case of a 35-year-old male with radial club hand who presented with a transverse fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Orthopaedic Surgery and Research
دوره 3 شماره
صفحات -
تاریخ انتشار 2008