Partial Volume Correction in PET/CT
نویسنده
چکیده
In this thesis, a two-dimensional pixel-wise deconvolution method for partial volume correction (PVC) for combined Positron Emission Tomography and Computer Tomography (PET/CT) imaging has been developed. The method is based on Van Cittert's deconvolution algorithm and includes a noise reduction method based on adaptive smoothing and median filters. Furthermore, a technique to take into account the position dependent PET point spread function (PSF) and to reduce ringing artifacts is also described. The quantitative and qualitative performance of the proposed PVC algorithm was evaluated using phantom experiments with varying object size, background and noise level. PVC results in an increased activity recovery as well as image contrast enhancement. However, the quantitative performance of the algorithm is impaired by the presence of background activity and image noise. When applying the correction on clinical PET images, the result was an increase in standardized uptake values, up to 98% for small tumors in the lung. These results suggest that the PVC described in this work significantly improves activity recovery without producing excessive amount of ringing artifacts and noise amplification. The main limitations of the algorithm are the restriction to two dimensions and the lack of regularization constraints based on anatomical information from the co-registered CT images.
منابع مشابه
Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملThe feasibility of 11C‐PIB‐PET/CT for amyloid plaque burden: validation of the effectiveness of CT‐based partial volume correction
INTRODUCTION Amyloid positron-emission tomography (PET) imaging with 11C-Pittsburgh compound B (PiB) is an effective tool for assessing brain amyloid deposits. PET imaging, however, can suffer from the partial volume effect (PVE). PVE has been corrected using MRI (magnetic resonance imaging) image data. However, correction of the PVE of PET using MRI usually requires two separate procedures, im...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملEffect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis
Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...
متن کاملEstimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom
One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...