Optic Nerve Sheath as a Novel Mechanical Load on the Globe in Ocular Duction
نویسنده
چکیده
PURPOSE The optic nerve (ON) sheath's role in limiting duction has been previously unappreciated. This study employed magnetic resonance imaging (MRI) to demonstrate this constraint on adduction. METHODS High-resolution, surface coil axial MRI was obtained in 11 normal adults, 14 subjects with esotropia (ET) having normal axial length (AL) < 25.8 mm, 13 myopic subjects with ET and mean AL 29.3 ± 3.3 (SD) mm, and 7 subjects with exotropia (XT). Gaze angles and ON lengths were measured for scans employing eccentric lateral fixation in which an ON became completely straightened. RESULTS In all groups, ON straightening occurred only in the adducting, not abducting, eye. Adduction at ON straightening was 26.0 ± 8.8° in normal subjects, not significantly different from XT at 22.2 ± 11.8°. However, there was significant increase in comparable adduction in ET to 36.3 ± 9.3°, and in myopic ET to 33.6 ± 10.7° (P < 0.04). Optic nerve length at straightening was 27.6 ± 2.7 mm in normals, not significantly different from 28.2 ± 2.8 mm in ET and 27.8 ± 2.7 mm in XT. In myopic ET, ON length at straightening was significantly reduced to 24.0 ± 2.9 mm (P < 0.002) and was associated with globe retraction in adduction, suggesting ON tethering. CONCLUSIONS Large adduction may exhaust length redundancy in the normally sinuous ON and sheath, so that additional adduction must stretch the sheath and retract or deform the globe. These mechanical effects are most significant in ET with axial myopia, but may also exert traction on the posterior sclera absent strabismus or myopia. Tethering by the ON sheath in adduction is an important, novel mechanical load on the globe.
منابع مشابه
Effect of scuba-diving on optic nerve and sheath diameters
Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...
متن کاملOcular motility changes after subtenon carboplatin chemotherapy for retinoblastoma.
BACKGROUND Focal subtenon carboplatin injections have recently been used as a presumably toxicity-free adjunct to systemic chemotherapy for intraocular retinoblastoma. OBJECTIVE To report our clinical experience with abnormal ocular motility in patients treated with subtenon carboplatin chemotherapy. METHODS We noted abnormal ocular motility in 10 consecutive patients with retinoblastoma wh...
متن کاملProgressive Deformation of the Optic Nerve Head and Peripapillary Structures by Graded Horizontal Duction
Purpose We investigated the effect of graded range of horizontal duction on the shape of the peripapillary Bruch's membrane (ppBM) and optic nerve head (ONH). Methods In 50 eyes of 25 normal subjects, the ONH and peripapillary retina were imaged by optical coherence tomography (OCT) in central gaze and incremental angles of add- and abduction. Displacements of the Bruch's membrane opening (BM...
متن کاملA unique model for ultrasound assessment of optic nerve sheath diameter.
BACKGROUND Ultrasonic assessment of optic nerve sheath diameter (ONSD) as a non-invasive measure of intracranial pressure (ICP) has been evaluated in the literature as a potential valid technique for rapid ICP estimation in the absence of invasive intracranial monitoring. The technique can be challenging to perform and little literature exists surrounding intra-operator variability. OBJECTIVE...
متن کاملOptic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure
A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches. The headaches were prolonged, generalised, and unusually severe for the patient. Examination revealed papilloedema. The patient's optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm. The patient subsequently had computed tomog...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 57 شماره
صفحات -
تاریخ انتشار 2016