Integrated electrokinetic magnetic bead-based electrochemical immunoassay on microfluidic chips for reliable control of permitted levels of zearalenone in infant foods.

نویسندگان

  • Mirian Hervás
  • Miguel A López
  • Alberto Escarpa
چکیده

Microfluidic technology has now become a novel sensing platform where different analytical steps, biological recognition materials and suitable transducers can be cleverly integrated yielding a new sensor generation. A novel "lab-on-a-chip" strategy integrating an electrokinetic magnetic bead-based electrochemical immunoassay on a microfluidic chip for reliable control of permitted levels of zearalenone in infant foods is proposed. The strategy implies the creative use of the simple channel layout of the double-T microchip to perform sequentially the immunointeraction and enzymatic reaction by applying a program of electric fields suitably connected to the reservoirs for driving the fluidics at different chambers in order to perform the different reactions. Both zones are used with the aid of a magnetic field to avoid in a very simple and elegant way the non-specific adsorption. Immunological reaction is performed under a competitive enzyme-linked immunosorbent assay (ELISA) where the mycotoxin ZEA and an enzyme-labelled derivative compete for the binding sites of the specific monoclonal antibody immobilised onto protein G modified magnetic beads. Horseradish peroxidase (HRP), in the presence of hydrogen peroxide, catalyses the oxidation of hydroquinone (HQ) to benzoquinone (BQN), whose back electrochemical reduction was detected at +0.1 V. Controlled-electrokinetic fluidic handling optimized conditions are addressed for all analytical steps cited above, and allows performing the complete immunoassay for the target ZEA analyte in less than 15 minutes with unique analytical merits: competitive immunoassay currents showed a very well-defined concentration dependence with a good precision as well as a suitable limit of detection of 0.4 µg L(-1), well below the legislative requirements, and an extremely low systematic error of 2% from the analysis of a maize certified reference material revealing additionally an excellent accuracy. Also, the reliability of the approach is demonstrated by the analysis of selected infant foods yielding the strictest ZEA permitted levels and excellent recoveries of 103 and 101% for solid and liquid samples, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated microfluidic platform of bead-based electrochemical immunosensor integrated with bioreactor for continual monitoring of cell secreted biomarkers.

There is an increasing interest in developing microfluidic bioreactors and organs-on-a-chip platforms combined with sensing capabilities for continual monitoring of cell-secreted biomarkers. Conventional approaches such as ELISA and mass spectroscopy cannot satisfy the needs of continual monitoring as they are labor-intensive and not easily integrable with low-volume bioreactors. This paper rep...

متن کامل

Magnetic control of an electrochemical microfluidic device with an arrayed immunosensor for simultaneous multiple immunoassays.

BACKGROUND Methods based on magnetic bead probes have been developed for immunoassay, but most involve complicated labeling or stripping procedures and are unsuitable for routine use. METHODS We synthesized magnet core/shell NiFe(2)O(4)/SiO(2) nanoparticles and fabricated an electrochemical magnetic controlled microfluidic device for the detection of 4 tumor markers. The immunoassay system co...

متن کامل

A Magnetic-bead-based Immunoassay for Rapid Purifica- Tion and Detection of Influenza Viruses Utilizing Suction- Type Microfluidic Systems

The study presents a magnetic-bead-based, suction-type microfluidic system for rapid purification and detection of influenza viral particles from clinical serum samples. Target influenza viral particles in the clinical sample can be first captured by the antibody-conjugated magnetic beads, followed by isolating the viral particles from the bio-samples with the incorporation of a permanent magne...

متن کامل

Self-assembled magnetic bead chains for sensitivity enhancement of microfluidic electrochemical biosensor platforms.

In this paper, we present a novel approach to enhance the sensitivity of microfluidic biosensor platforms with self-assembled magnetic bead chains. An adjustable, more than 5-fold sensitivity enhancement is achieved by introducing a magnetic field gradient along a microfluidic channel by means of a soft-magnetic lattice with a 350 μm spacing. The alternating magnetic field induces the self-asse...

متن کامل

Heterogeneous immunoassays using magnetic beads on a digital microfluidic platform.

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore doe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 136 10  شماره 

صفحات  -

تاریخ انتشار 2011