Continuous oxygen saturation monitoring during cardiac catheterization in adults.

نویسندگان

  • S R Dodson
  • F A Hensley
  • D E Martin
  • D R Larach
  • D L Morris
چکیده

Arterial hypoxemia may contribute to morbidity during cardiac catheterization. Therefore, we measured arterial hemoglobin oxygen saturation (SaO2) continuously using pulse oximetry in 29 patients (age range, 21 to 83 years) undergoing cardiac catheterization. Baseline SaO2 was 96 +/- 0.4 percent. All patients had a decrease in SaO2 at some time during the procedure. Eleven patients (38 percent) had episodes of arterial hypoxemia, defined as a decrease in SaO2 below 90 percent. In these 11 patients, the mean number of episodes of hypoxemia was 16 +/- 7, and the mean duration of each episode was 53 +/- 25 seconds. Multiple stepwise regression analysis showed that the minimum SaO2 during catheterization for any patient was significantly associated with the baseline SaO2, duration of the procedure, and end-diastolic volume (EDV) as described by the following regression equation: minimum SaO2 = 46.8 - 0.0580 (duration of procedure in minutes) + 0.5362 (baseline SaO2) - 0.0159 (EDV). Based on our finding of arterial hypoxemia in greater than one third of our patients, we would consider continuous SaO2 monitoring or supplemental oxygen during cardiac catheterization, especially for those patients with poor ventricular function or low resting SaO2 or those expected to have long procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term recording of cardiac output via an implantable haemodynamic monitoring device.

Long-term monitoring of central haemodynamics with implanted monitoring systems might be valuable in managing heart failure patients. Such systems offer an opportunity for repeated 'semi-invasive' cardiac output determinations according to the Fick principle. Five patients, four with chronic heart failure and one with chronic pulmonary disease, underwent supine exercise testing during cardiac c...

متن کامل

The pitfalls of bedside regional cerebral oxygen saturation in the early stage of post cardiac arrest

It remains uncertain whether neuromonitoring reliably predicts outcome in adult post-cardiac arrest patients in the early stage treated with therapeutic hypothermia. Recent reports demonstrated a regional cerebral oxygen saturation of cardiac arrest patients on hospital arrival could predict their neurological outcome. There has been little discussion about the significance of regional cerebral...

متن کامل

Should We Monitor ScVO2 in Critically Ill Patients?

Hemodynamic monitoring has become a real challenge in the intensive care unit. As an integrative parameter for oxygen supply/demand, venous oxygen saturation (SvO(2)) provided by pulmonary artery catheterization is one of the most popular parameters to assess the adequacy of cardiac output. However, technical limitations and potential iatrogenic complications constitute important limits for a w...

متن کامل

Utility of an implantable right ventricular oxygen saturation-sensing pacemaker for ambulatory cardiopulmonary monitoring.

Mixed venous oxygen saturation (SvO2) is a physiologic parameter reflecting cardiac output (CO) and tissue oxygen utilization. An implantable oxygen sensor incorporated in a right ventricular pacing lead has been developed to assess the feasibility of ambulatory monitoring of SvO2 to predict cardiorespiratory parameters. Eight patients with a mean age of 62 +/- 2 years and sinoatrial disease re...

متن کامل

Continuous monitoring of mixed venous oxygen saturation during aortic surgery.

The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 94 1  شماره 

صفحات  -

تاریخ انتشار 1988