Multipoint Pacing versus conventional ICD in Patients with a Narrow QRS complex (MPP Narrow QRS trial): study protocol for a pilot randomized controlled trial

نویسندگان

  • Maurizio Gasparini
  • Paola Galimberti
  • Renato Bragato
  • Stefano Ghio
  • Claudia Raineri
  • Maurizio Landolina
  • Enrico Chieffo
  • Maurizio Lunati
  • Ederina Mulargia
  • Alessandro Proclemer
  • Domenico Facchin
  • Roberto Rordorf
  • Alessandro Vicentini
  • Lina Marcantoni
  • Francesco Zanon
  • Catherine Klersy
چکیده

BACKGROUND Despite an intensive search for predictors of the response to cardiac resynchronization therapy (CRT), the QRS duration remains the simplest and most robust predictor of a positive response. QRS duration of ≥ 130 ms is considered to be a prerequisite for CRT; however, some studies have shown that CRT may also be effective in heart failure (HF) patients with a narrow QRS (<130 ms). Since CRT can now be performed by pacing the left ventricle from multiple vectors via a single quadripolar lead, it is possible that multipoint pacing (MPP) might be effective in HF patients with a narrow QRS. This article reports the design of the MPP Narrow QRS trial, a prospective, randomized, multicenter, controlled feasibility study to investigate the efficacy of MPP using two LV pacing vectors in patients with a narrow QRS complex (100-130 ms). METHODS Fifty patients with a standard ICD indication will be enrolled and randomized (1:1) to either an MPP group or a Standard ICD group. All patients will undergo a low-dose dobutamine stress echo test and only those with contractile reserve will be included in the study and randomized. The primary endpoint will be the percentage of patients in each group that have reverse remodeling at 12 months, defined as a reduction in left ventricular end-systolic volume (LVESV) of >15% from the baseline. DISCUSSION This feasibility study will determine whether MPP improves reverse remodeling, as compared with standard ICD, in HF patients who have a narrow QRS complex (100-130 ms). TRIAL REGISTRATION ClinicalTrials.gov, NCT02402816 . Registered on 25 March 2015.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac resynchronization therapy in patients with a narrow QRS.

Although cardiac resynchronization therapy (CRT) is indicated in patients with moderate to severe heart failure with a wide QRS complex (> 120 ms), current guidelines exclude many heart failure patients with a narrow QRS. Detecting mechanical dyssynchrony on echocardiography has become a promising tool in selecting patients with a narrow QRS who may respond to CRT. Several small single-center s...

متن کامل

Multipoint pacing via a quadripolar left-ventricular lead: preliminary results from the Italian registry on multipoint left-ventricular pacing in cardiac resynchronization therapy (IRON-MPP)

Aims This registry was created to describe the experience of 76 Italian centres with a large cohort of recipients of multipoint pacing (MPP) capable cardiac resynchronization therapy (CRT) devices. Methods and results A total of 507 patients in whom these devices had been successfully implanted were enrolled between August 2013 and May 2015. We analysed: (i) current clinical practices for the...

متن کامل

Cardiac-resynchronization therapy in patients with systolic heart failure and QRS interval ≤130 ms: insights from a meta-analysis.

AIMS Cardiac-resynchronization therapy (CRT) reduces morbidity and mortality in patients with chronic systolic heart failure (SHF) and a wide QRS complex. It is unclear whether the same benefit extends to patients with QRS duration (QRSd) <130 ms. METHODS AND RESULTS Our aim was to perform a meta-analysis of all randomized controlled trial (RCTs) and to evaluate the effect of implantable CRT ...

متن کامل

Effect of Gender on Outcomes After Cardiac Resynchronization Therapy in Patients With a Narrow QRS Complex: A Subgroup Analysis of the EchoCRT Trial.

BACKGROUND In EchoCRT, a randomized controlled trial evaluating the effect of cardiac resynchronization therapy (CRT) in patients with a QRS duration of <130 ms and echocardiographic evidence of left ventricular dyssynchrony, the primary outcome (death from any cause or first hospitalization for worsening heart failure) occurred more frequently in the CRT-ON when compared with the control group...

متن کامل

Effect of Study Design on the Reported Effect of Cardiac Resynchronization Therapy (CRT) on Quantitative Physiological Measures: Stratified Meta‐Analysis in Narrow‐QRS Heart Failure and Implications for Planning Future Studies

BACKGROUND Biventricular pacing (CRT) shows clear benefits in heart failure with wide QRS, but results in narrow QRS have appeared conflicting. We tested the hypothesis that study design might have influenced findings. METHOD AND RESULTS We identified all reports of CRT-P/D therapy in subjects with narrow QRS reporting effects on continuous physiological variables. Twelve studies (2074 patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016