Leadless Pacing: Current State and Future Direction

نویسندگان

  • Matthias Merkel
  • Philipp Grotherr
  • Andrea Radzewitz
  • Claus Schmitt
چکیده

Leadless pacing is now an established alternative to conventional pacing with subcutaneous pocket and transvenous lead for patients with class I or II single-chamber pacing indication. Available 12-month follow-up data shows a 48% fewer major complication rate in patients with Micra™ compared to a historical control group in a nonrandomized study [1]. There is one system with Food and Drug Administration (FDA) approval and two with the Communauté Européenne (CE) mark. The OPS code for the implantation is 8-83d.3 and the procedure has recently been rated as a "new Examination and Treatment Method (NUB)" in the German DRG system, meaning adequate reimbursement is negotiable with health insurance providers. The systems offer similar generator longevity and programming possibilities as conventional pacemaker systems, including rate response, remote monitoring, and MRI safety. The biggest downsides to date are limitations to single-chamber stimulation, lack of long-time data, and concerns of handling of the system at the end of its life span. However, implant procedure complication rates and procedure times do not exceed conventional pacemaker operations, and proper training and patient selection is provided.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Advances in Pacing and Defibrillation

Most current pacemaker and ICD systems involve placement of lead(s) transvenously into the heart, connected to a pulse generator. Vascular access may be difficult or limited in some patients, and intravascular leads can be associated with multiple complications such as infection, lead malfunction and vascular occlusion. Recent advances in pacing and ICDs include the development of subcutaneous ...

متن کامل

ECGs and Pacemakers

Leadless pacemakers will most likely be the future of cardiac pacing. Leadless pacing employs a singlechamber system to pace only the right ventricle and is fully self-contained, which eliminates the need for leads. These systems, implanted by using a transcatheter sheath, are indicated for patients who need right ventricular pacing only. These devices enable patients to avoid lead-related comp...

متن کامل

Leadless Cardiac Pacemakers: Back to the Future.

Despite significant advances in battery longevity, lead performance, and programming features since the first implanted permanent pacemaker was developed, the basic design of cardiac pacemakers has remained relatively unchanged over the past 50 years. Because of inherent limitations in their design, conventional (transvenous) pacemakers are prone to multiple potential short- and long-term compl...

متن کامل

State of the art of leadless pacing.

Despite undisputable benefits, conventional pacemaker therapy is associated with specific complications related to the subcutaneous device and the transvenous leads. Recently, two miniaturized leadless pacemakers, Nanostim™ (St. Jude Medical) and Micra™ (Medtronic), which can be completely implanted inside the right ventricle using steerable delivery systems, entered clinical application. The W...

متن کامل

Feasibility of Leadless Cardiac Pacing Using Injectable Magnetic Microparticles

A noninvasive, effective approach for immediate and painless heart pacing would have invaluable implications in several clinical scenarios. Here we present a novel strategy that utilizes the well-known mechano-electric feedback of the heart to evoke cardiac pacing, while relying on magnetic microparticles as leadless mechanical stimulators. We demonstrate that after localizing intravenously-inj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017